{"id":33938,"date":"2022-02-14T05:38:35","date_gmt":"2022-02-14T05:38:35","guid":{"rendered":"https:\/\/www.takomabattery.com\/?p=33938"},"modified":"2022-04-20T02:29:01","modified_gmt":"2022-04-20T02:29:01","slug":"how-to-use-ups-ups-failure-analysis","status":"publish","type":"post","link":"https:\/\/www.takomabattery.com\/es\/how-to-use-ups-ups-failure-analysis\/","title":{"rendered":"C\u00f3mo utilizar el an\u00e1lisis de fallos ups\uff1aups."},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"33938\" class=\"elementor elementor-33938\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9496242 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9496242\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7c4b602\" data-id=\"7c4b602\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5eea69b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5eea69b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ae9bbf3\" data-id=\"ae9bbf3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b153248 elementor-widget elementor-widget-heading\" data-id=\"b153248\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">c\u00f3mo utilizar ups\uff1aups an\u00e1lisis de fallos.<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1c5f788 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1c5f788\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-37bc313\" data-id=\"37bc313\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-175ef07 elementor-widget elementor-widget-text-editor\" data-id=\"175ef07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div style=\"padding-left: 2.2em; padding-right: 2.2em; line-height: 40px;\"><div style=\"border: 2px solid #ccc;\"><ol style=\"padding-left: 2.2em; line-height: 40px;\"><li><a href=\"#Troubleshooting_method\">M\u00e9todo de resoluci\u00f3n de problemas<\/a><ol style=\"counter-reset: item;\"><li><a href=\"#Observation_method\">M\u00e9todo de observaci\u00f3n<\/a><\/li><li><a href=\"#Graded_compression_test\">Ensayo de compresi\u00f3n graduada<\/a><\/li><li><a href=\"#Other_special_methods\">Otros m\u00e9todos especiales<\/a><\/li><\/ol><\/li><li><a href=\"#UPS_common_faults\">Aver\u00edas comunes del SAI<\/a><ol style=\"counter-reset: item;\"><li><a href=\"#Invariant\">Invariante<\/a><\/li><li><a href=\"#Unregulated_voltage\">Tensi\u00f3n no regulada<\/a><\/li><li><a href=\"#Not_charging\">No carga<\/a><\/li><li><a href=\"#Can_not_use_mains_electricity\">No puede utilizar la red el\u00e9ctrica<\/a><\/li><li><a href=\"#UPS_cannot_start_normally\">El SAI no puede arrancar normalmente<\/a><\/li><li><a href=\"#UPS_frequently_switches_to_bypass_mode_during_operation\">El SAI cambia con frecuencia al modo de derivaci\u00f3n durante el funcionamiento<\/a><\/li><li><a href=\"#When_the_utility_power_is_interrupted,_the_UPS_will_also_automatically_stop\">Cuando se interrumpe el suministro el\u00e9ctrico, el SAI tambi\u00e9n se detiene autom\u00e1ticamente.<\/a><\/li><\/ol><\/li><li><a href=\"#UPS_human_failure\">Fallo humano del SAI<\/a><ol style=\"counter-reset: item;\"><li><a href=\"#Suspected_failure\">Sospecha de fallo<\/a><\/li><li><a href=\"#Knowledge_failure\">Fallo de conocimiento<\/a><\/li><li><a href=\"#Operation_failure\">Fallo de funcionamiento<\/a><\/li><li><a href=\"#Delay_failure\">Fallo de retardo<\/a><\/li><li><a href=\"#Maintenance_failure\">Fallo de mantenimiento<\/a><\/li><li><a href=\"#Experience_failure\">Fracaso de la experiencia<\/a><\/li><li><a href=\"#Handover_failure\">Fallo de transferencia<\/a><\/li><\/ol><\/li><\/ol><\/div><p>Cuando el sistema SAI falla, primero hay que averiguar la causa y distinguir si es la carga o el sistema SAI, el host o el pack de bater\u00edas. Aunque el host del SAI dispone de una funci\u00f3n de autocomprobaci\u00f3n de fallos, sigue siendo necesario un gran trabajo de an\u00e1lisis y pruebas para reparar el punto de fallo.<\/p><p>Cuando falle el SAI de la carga importante, no lo apague a ciegas, sino que utilice su derivaci\u00f3n para seguir suministrando energ\u00eda y, a continuaci\u00f3n, averig\u00fce la causa y determine si el fallo se produce en la carga o en el sistema SAI. Si falla el sistema SAI, determine adem\u00e1s si el fallo se produce en el host del SAI o en el paquete de bater\u00edas.<\/p><p>Adem\u00e1s, si falla la parte de autodiagn\u00f3stico, el contenido de fallo mostrado puede ser err\u00f3neo. En caso de aver\u00eda del ordenador central, rotura del fusible o quemadura del dispositivo, es necesario averiguar la causa y eliminar el fallo antes de reiniciar, de lo contrario el fallo del sistema SAI se ampliar\u00e1 a\u00fan m\u00e1s.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-33941\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand.jpg\" alt=\"es necesario averiguar la causa y eliminar el fallo antes de reiniciar, de lo contrario el fallo del sistema SAI se ampliar\u00e1 a\u00fan m\u00e1s\" width=\"1000\" height=\"678\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand-300x203.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand-768x521.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand-600x407.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h2 id=\"Troubleshooting_method\">M\u00e9todo de resoluci\u00f3n de problemas<\/h2><p>Los SAI son sistemas de alimentaci\u00f3n ininterrumpida, y su carga requiere que el suministro el\u00e9ctrico no pueda interrumpirse. Una vez que el SAI tenga un problema, afectar\u00e1 inevitablemente a la carga conectada. Por lo tanto, el personal de operaci\u00f3n y mantenimiento del SAI debe estar familiarizado con el equipo utilizado. Debe ser capaz de hacer frente a sus aver\u00edas comunes de manera oportuna. A continuaci\u00f3n se presentan varios m\u00e9todos b\u00e1sicos para la resoluci\u00f3n de problemas.<\/p><h4 id=\"Observation_method\">M\u00e9todo de observaci\u00f3n<\/h4><p>El m\u00e9todo de observaci\u00f3n es el m\u00e1s sencillo, directo y pr\u00e1ctico en la localizaci\u00f3n de aver\u00edas de equipos. Este m\u00e9todo consiste en utilizar los sentidos humanos para juzgar inicialmente y eliminar los fallos de los equipos. Cuando se utiliza el m\u00e9todo de observaci\u00f3n para detectar fallos, se puede ir de lo simple a lo complejo, de lo externo a lo interno, y despu\u00e9s, bas\u00e1ndose en la acumulaci\u00f3n de experiencia adecuada, centrarse en los circuitos o piezas propensos a fallos. La inspecci\u00f3n tiene un efecto multiplicador. El m\u00e9todo de observaci\u00f3n se centra en los cuatro aspectos de ver, escuchar, oler y tocar.<\/p><p>\"Observaci\u00f3n\" es el primer paso del fallo de contacto, que incluye: comprobar si hay un cortocircuito causado por objetos extra\u00f1os superpuestos en el equipo. Segundo, comprobar si hay un circuito abierto en el equipo, o si hay un cable seriamente da\u00f1ado o roto, prestar especial atenci\u00f3n al cable o Si las partes aislantes de otros componentes est\u00e1n seriamente da\u00f1adas. Tercero, comprobar si los componentes est\u00e1n deformados o agrietados. Cuarto, compruebe si los tornillos de conexi\u00f3n del equipo est\u00e1n flojos, y si el contacto de cada conector es bueno. Condiciones de oscurecimiento o humo.<\/p><p>El contenido que hay que ver tambi\u00e9n incluye el tir\u00f3n de contactores y rel\u00e9s, las condiciones de luz y oscuridad de varios indicadores, el estallido de condensadores electrol\u00edticos y condensadores de CA, etc. Una parte considerable de la aver\u00eda puede detectarse observ\u00e1ndola, de modo que el equipo puede volver a funcionar lo antes posible.<\/p><p>\"Escuchar\" es escuchar si hay alg\u00fan sonido anormal durante el funcionamiento del equipo. Durante el funcionamiento del equipo SAI, el contactor y el rel\u00e9 emitir\u00e1n un sonido, y el transformador, la reactancia y otras bobinas bajo tensi\u00f3n emitir\u00e1n un sonido \u00fanico al funcionar. Estos sonidos tienen ciertas reglas y ritmos. Si estos componentes fallan, sus sonidos cambiar\u00e1n. Seg\u00fan estos cambios, se puede encontrar el fallo del equipo SAI.<\/p><p>\"Oler\" es utilizar los \u00f3rganos olfativos humanos para percibir los equipos dentro de un determinado rango. Por ejemplo, despu\u00e9s de que la capa exterior aislante de los conductores o de algunos componentes se chamusque o se despegue debido al paso excesivo de corriente, se produce un olor acre y desagradable.<\/p><p>Por lo tanto, dentro de un cierto rango, este olor anormal puede recordar al personal de mantenimiento que existe una situaci\u00f3n anormal en el funcionamiento del equipo, y la aver\u00eda puede eliminarse buscando cuidadosamente la fuente del olor extra\u00f1o. \"Tocar\" es utilizar las manos para entrar en contacto con algunos componentes que son propensos a fallar o componentes que pueden causar fallos despu\u00e9s de juzgarlos, con el fin de ayudar a los operadores y al personal de mantenimiento a encontrar y eliminar fallos.<\/p><p>Por ejemplo, en el caso de sospecha de fallos de soldadura o de sudor fr\u00edo, puede detectarse tocando ligeramente o sacudiendo, y la percepci\u00f3n de la temperatura puede determinarse por la experiencia. En el SAI hay muchos elementos calefactores. Cuando el equipo est\u00e1 funcionando, fluye corriente, y la temperatura de algunos componentes aumentar\u00e1. Mientras la temperatura no supere el valor permitido, el estado de funcionamiento del equipo no se ver\u00e1 afectado.<\/p><p><img decoding=\"async\" class=\"aligncenter size-full wp-image-33942\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected.jpg\" alt=\"Mientras la temperatura no supere el valor permitido, el estado de funcionamiento del equipo no se ver\u00e1 afectado.\" width=\"1000\" height=\"519\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected-300x156.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected-768x399.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected-600x311.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><p>Sin embargo, si se detecta que un determinado componente est\u00e1 sobrecalentado y la temperatura aumenta repentinamente, es posible que el equipo haya fallado o vaya a fallar. En ese momento, podemos encontrar la aver\u00eda en funci\u00f3n de la fuente de calor y analizar la causa. \"Tocar\" requiere experiencia acumulada en el trabajo normal, pero no est\u00e1 permitido manipularlo. En lugares con alta temperatura, alto voltaje u otros inconvenientes al tacto, no lo manipule f\u00e1cilmente para evitar lesiones personales o afectar el funcionamiento normal del equipo.<\/p><p>En resumen, el m\u00e9todo de observaci\u00f3n puede tratar la aver\u00eda de forma directa y r\u00e1pida. Los m\u00e9todos de \"observaci\u00f3n, escucha, olfato y tacto\" no son independientes entre s\u00ed, y pueden utilizarse solos o combinados. Por ejemplo, debido a la corriente de cortocircuito Si es demasiado grande para provocar que un cable determinado se chamusque, el cambio de su color se puede encontrar mirando, o la transmisi\u00f3n de olor peculiar se puede percibir oliendo, y se puede encontrar la fuente de la aver\u00eda.<\/p><p>Por \u00faltimo, hay que tener en cuenta algunos circuitos con un alto \u00edndice de fallos.<\/p><h4 id=\"Graded_compression_test\">Ensayo de compresi\u00f3n graduada<\/h4><p>En la soluci\u00f3n de problemas del SAI, aunque el m\u00e9todo de observaci\u00f3n es m\u00e1s eficaz, hay muchos fallos que no se pueden encontrar por el m\u00e9todo de observaci\u00f3n, y deben ser juzgados por ciertos m\u00e9todos de prueba, con el fin de averiguar la causa del fallo y tomar los m\u00e9todos de compresi\u00f3n necesarios, a fin de corregir el fallo. Reducir hasta la localizaci\u00f3n de aver\u00edas.<\/p><p>La compresi\u00f3n jer\u00e1rquica consiste en analizar y juzgar algunos fallos cuyo alcance no est\u00e1 claro y, a continuaci\u00f3n, probarlos paso a paso para comprimirlos y encontrarlos. Existen diferentes m\u00e9todos de compresi\u00f3n en funci\u00f3n del tipo de aver\u00eda del equipo o de los m\u00e9todos de mantenimiento individuales. Por ejemplo, hay puntuaci\u00f3n media + m\u00e9todo de medici\u00f3n de resistencia, puntuaci\u00f3n media + m\u00e9todo de medici\u00f3n de presi\u00f3n, etc.<\/p><p>Estos m\u00e9todos son inseparables de los m\u00e9todos est\u00e1tico y din\u00e1mico. El m\u00e9todo est\u00e1tico de medici\u00f3n de la resistencia se utiliza para comprobar si el circuito es normal y, finalmente, la aver\u00eda se comprime hasta un punto; el din\u00e1mico se utiliza para detectar si la tensi\u00f3n y la forma de onda del circuito correspondiente son normales cuando el equipo est\u00e1 trabajando para comprimir la aver\u00eda. Ambos m\u00e9todos de mantenimiento aumentan la velocidad de mantenimiento al adoptar el m\u00e9todo de compresi\u00f3n segmentada.<\/p><p>El m\u00e9todo de mantenimiento que utiliza la compresi\u00f3n de subsecci\u00f3n consiste en analizar y determinar si el circuito en cuesti\u00f3n es an\u00f3malo probando algunos valores de tensi\u00f3n, valores de corriente y formas de onda. Por lo tanto, el personal de mantenimiento debe ser capaz de memorizar y probar correctamente la forma de onda normal, el valor de tensi\u00f3n y el rango de valores de corriente de algunos puntos de trabajo importantes.<\/p><p>Los puntos generales de trabajo importantes son: Entrada de alimentaci\u00f3n de CA, extremo de entrada (salida) del rectificador, extremo de entrada (salida) del inversor, extremo de salida del dispositivo de filtrado, extremo de salida de la bater\u00eda, dispositivo de conmutaci\u00f3n de alta potencia y cada circuito impreso La fuente de alimentaci\u00f3n de trabajo, etc. seguido de los puntos de tensi\u00f3n relevantes y los puntos de forma de onda en cada circuito de control, compare la situaci\u00f3n de prueba con el valor normal y, a continuaci\u00f3n, analice el alcance del fallo. Solucione los problemas m\u00e1s r\u00e1pidamente.<\/p><p>Para la prueba del valor de la tensi\u00f3n, el valor de la corriente y la forma de onda, si el valor normal no est\u00e1 claro, si las condiciones lo permiten, se puede probar la tensi\u00f3n, la corriente y la forma de onda del punto correspondiente del mismo equipo que funciona normalmente. Ambos se comparan para analizar y juzgar la aver\u00eda.<\/p><h4 id=\"Other_special_methods\">Otros m\u00e9todos especiales<\/h4><p>Para algunos fen\u00f3menos especiales de fallo o puntos de fallo, es dif\u00edcil eliminarlos por m\u00e9todos ordinarios, por lo que podemos utilizar algunos m\u00e9todos especiales para comprobar y comprimir. Por ejemplo, alg\u00fan mal contacto causado por la soldadura en fr\u00edo, soldadura virtual, desgaste del contacto, oxidaci\u00f3n, herrumbre, etc. puede causar f\u00e1cilmente que el equipo SAI funcione bien y mal. Cuando es anormal, el personal de mantenimiento lo comprueba y comprime all\u00ed, y la aver\u00eda puede desaparecer de repente. , Para fallos intermitentes como este, generalmente es m\u00e1s efectivo utilizar el m\u00e9todo de vibraci\u00f3n de grifo para comprobar.<\/p><p><img decoding=\"async\" class=\"aligncenter size-full wp-image-33943\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust.jpg\" alt=\"alg\u00fan contacto deficiente causado por soldadura en fr\u00edo, soldadura virtual, desgaste del contacto, oxidaci\u00f3n, herrumbre\" width=\"1000\" height=\"750\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust-300x225.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust-768x576.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust-600x450.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><p>En el m\u00e9todo de vibraci\u00f3n por golpeteo, debe tenerse en cuenta que la vibraci\u00f3n por golpeteo no debe ser demasiado fuerte. Si hay dudas sobre una determinada pieza, no debe causar una vibraci\u00f3n excesiva en otros lugares debido al golpeteo de esta pieza, y no debe causar nuevos fallos debido a un golpeteo excesivo. S\u00f3lo puede realizarse de forma moderada. Al golpear, no utilice objetos met\u00e1licos para evitar ara\u00f1azos o provocar cortocircuitos.<\/p><p>El equipo SAI puede fallar debido al aumento de la temperatura ambiente o al aumento de la temperatura de funcionamiento dentro del propio equipo. Tras un periodo de parada, el equipo puede reiniciarse a medida que la temperatura disminuye, y el equipo puede volver a funcionar con normalidad. Sin embargo, al aumentar la temperatura de funcionamiento, el equipo vuelve a fallar.<\/p><p>Para estos fen\u00f3menos anormales debidos al aumento de la temperatura, el mejor m\u00e9todo de mantenimiento y compresi\u00f3n es utilizar el m\u00e9todo de calentamiento local. El m\u00e9todo de calentamiento local se refiere a la localizaci\u00f3n de aver\u00edas y compresi\u00f3n del equipo. Para algunas partes dudosas, utilice medios de calentamiento, eleve artificialmente la temperatura para la inspecci\u00f3n, la fuente de calor puede ser un cuerpo de calentamiento de seguridad o un secador de pelo, etc. Al calentar localmente, si el sistema falla, indica que el rendimiento t\u00e9rmico es malo. El elemento se encuentra en la zona de calentamiento. Cuando se calienta localmente, la temperatura debe controlarse adecuadamente. No debe ser demasiado baja, y el efecto ser\u00e1 pobre; no debe ser demasiado alta, que puede da\u00f1ar los componentes y causar nuevos fallos artificialmente.<\/p><p>Para algunas aver\u00edas complejas, especialmente cuando no se comprende bien el principio de funcionamiento interno de algunos componentes, cuando la inspecci\u00f3n se comprime a un nivel o a una secci\u00f3n determinada, se sospecha que algunos componentes son defectuosos, entonces podemos utilizar el m\u00e9todo alternativo para juzgar , el m\u00e9todo de sustituci\u00f3n se aplica a la misma placa de circuito impreso, a la misma unidad de circuito o a un componente espec\u00edfico.<\/p><p>Por ejemplo, cuando existen dudas sobre si un determinado componente es normal o no, se puede sustituir por componentes del mismo tipo y especificaci\u00f3n. Para ver si el fen\u00f3meno de fallo del equipo desaparece, para algunos componentes que son dif\u00edciles de determinar la especificaci\u00f3n del modelo, podemos utilizar componentes similares en su lugar, y si el fen\u00f3meno de fallo puede ser eliminado, significa que el fallo est\u00e1 efectivamente aqu\u00ed. El m\u00e9todo de sustituci\u00f3n tiene un campo de aplicaci\u00f3n muy amplio, especialmente en los equipos SAI importados que no disponen de planos de circuitos de referencia ni de indicadores de par\u00e1metros espec\u00edficos.<\/p><p>Existen varios m\u00e9todos de mantenimiento para las aver\u00edas del SAI. Es imposible resumirlos aqu\u00ed en detalle. Corresponde a cada uno mejorarlos continuamente en el proceso real de resoluci\u00f3n de problemas, y resumir un conjunto de m\u00e9todos de mantenimiento adecuados a su propia forma de pensar.<\/p><h2 id=\"UPS_common_faults\">Aver\u00edas comunes del SAI<\/h2><p>En circunstancias normales, los fallos m\u00e1s comunes de la placa base del SAI son la falta de paralelo, la falta de inversi\u00f3n, la falta de estabilizaci\u00f3n, la falta de carga, la imposibilidad de utilizar la alimentaci\u00f3n de red, el fallo de la bater\u00eda, el fallo del condensador, el fallo por interferencias y la aver\u00eda. Cuando se revisa el SAI, se debe comprobar primero la bater\u00eda, seguida del circuito de la placa base. Si se determina que el circuito de la placa base est\u00e1 defectuoso, se debe comprobar primero el circuito de alimentaci\u00f3n del regulador de tensi\u00f3n de red y, a continuaci\u00f3n, el circuito del inversor.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33945\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit.jpg\" alt=\"Al revisar el SAI, primero debe comprobarse la bater\u00eda, seguida del circuito de la placa base.\" width=\"1000\" height=\"563\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit-300x169.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit-768x432.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit-600x338.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"Invariant\">Invariante<\/h4><p>No inversor significa que el SAI funciona normalmente con alimentaci\u00f3n de red, pero la tensi\u00f3n de CC de la bater\u00eda no puede convertirse en tensi\u00f3n de CA de 220 V (o 380 V) cuando se interrumpe la alimentaci\u00f3n de red. En este caso, debe medirse primero la tensi\u00f3n de la bater\u00eda, ya que si la tensi\u00f3n de la bater\u00eda es demasiado baja, el circuito de control interrumpir\u00e1 el funcionamiento del circuito inversor tras detectar la se\u00f1al de baja tensi\u00f3n de la bater\u00eda.<\/p><p>A continuaci\u00f3n, compruebe si la alimentaci\u00f3n auxiliar es normal y si el tubo inversor y el tubo impulsor est\u00e1n da\u00f1ados. Por \u00faltimo, compruebe el circuito de protecci\u00f3n de salida. En circunstancias normales, el punto de fallo del SAI puede comprobarse y eliminarse mediante los pasos anteriores.<\/p><h4 id=\"Unregulated_voltage\">Tensi\u00f3n no regulada<\/h4><p>En el caso del SAI fuera de l\u00ednea, la tensi\u00f3n no regulada se divide en dos situaciones: la salida no est\u00e1 regulada cuando entra la corriente alterna y la salida del inversor no est\u00e1 regulada. Cuando entra la alimentaci\u00f3n comercial, el proceso de regulaci\u00f3n de la tensi\u00f3n de salida se realiza conectando el rel\u00e9 y las diferentes tomas del transformador a trav\u00e9s del circuito de regulaci\u00f3n de tensi\u00f3n.<\/p><p>El proceso de regulaci\u00f3n de tensi\u00f3n de la tensi\u00f3n de salida del variador se realiza controlando la anchura de pulso de la se\u00f1al de onda cuadrada mediante la detecci\u00f3n de la tensi\u00f3n de realimentaci\u00f3n del variador. Si el SAI no consigue estabilizar la tensi\u00f3n, basta con comprobar el circuito de control de regulaci\u00f3n de tensi\u00f3n correspondiente.<\/p><h4 id=\"Not_charging\">No carga<\/h4><p>El fallo de no carga es dif\u00edcil de encontrar en un entorno en el que la red el\u00e9ctrica no se interrumpe con frecuencia, y es muy perjudicial, y es probable que provoque el desguace anticipado de la bater\u00eda porque no se puede cargar durante mucho tiempo. El m\u00e9todo para juzgar este fallo es muy sencillo, siempre y cuando se desconecte la conexi\u00f3n entre el circuito de carga y la bater\u00eda, y se pueda juzgar la tensi\u00f3n en vac\u00edo del circuito de carga.<\/p><p>Cuando es normal, el voltaje de una sola bater\u00eda de 12V es de 13,5V, y el de dos bater\u00edas conectadas en serie es de 27V. Si la tensi\u00f3n es anormal, se debe comprobar el circuito de carga y el circuito de control correspondiente, especialmente el circuito de control relacionado. ; Cuando la tensi\u00f3n de red es demasiado baja o se interrumpe, el circuito de carga dejar\u00e1 de funcionar bajo la acci\u00f3n del circuito de control; si el circuito de control funciona mal y se aver\u00eda, el circuito de carga no funcionar\u00e1.<\/p><h4 id=\"Can_not_use_mains_electricity\">No puede utilizar la red el\u00e9ctrica<\/h4><p>La salida del variador es normal, y no hay salida cuando se utiliza la entrada de red. Cuando se encuentre con un fallo de este tipo, se debe comprobar primero el circuito de detecci\u00f3n de red, ya que cuando el circuito de detecci\u00f3n de red detecta que la tensi\u00f3n de la red es demasiado baja o demasiado alta, enviar\u00e1 la se\u00f1al correspondiente al circuito de control, para que \u00e9ste env\u00ede un impulso de control para cortar la red. Canal de entrada de alimentaci\u00f3n, y hacer que el SAI est\u00e9 en estado inversor.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33944\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit.jpg\" alt=\"Cuando el circuito de detecci\u00f3n es normal, compruebe finalmente el circuito de conversi\u00f3n del rel\u00e9\" width=\"1000\" height=\"563\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit-300x169.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit-768x432.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit-600x338.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><p>Cuando el circuito de detecci\u00f3n es normal, compruebe finalmente el circuito de conversi\u00f3n del rel\u00e9. Debido a los diferentes modelos, su relaci\u00f3n de control y los tipos de circuito de protecci\u00f3n tambi\u00e9n son muy diferentes. Hay muchas razones para el mismo fen\u00f3meno de fallo aqu\u00ed, pero de acuerdo con la experiencia, los m\u00e9todos de inspecci\u00f3n son b\u00e1sicamente los mismos.<\/p><h4 id=\"UPS_cannot_start_normally\">El SAI no puede arrancar normalmente<\/h4><p>En circunstancias normales, el SAI en l\u00ednea funcionar\u00e1 autom\u00e1ticamente en el modo de alimentaci\u00f3n en bypass mientras el interruptor de entrada est\u00e9 cerrado y la carga est\u00e9 alimentada directamente por la red el\u00e9ctrica. Cuando el SAI arranque durante un periodo de tiempo, cambiar\u00e1 autom\u00e1ticamente de alimentaci\u00f3n bypass a alimentaci\u00f3n inversor (modo de trabajo normal). Si no puede arrancar normalmente, significa que hay un problema con la bater\u00eda o el inversor. Compruebe la bater\u00eda o el inversor para averiguar el motivo.<\/p><p>Adem\u00e1s de los factores internos de la m\u00e1quina, las razones por las que el SAI no puede arrancar normalmente deben comprobar en primer lugar si la tensi\u00f3n de entrada es normal, y para el SAI con entrada trif\u00e1sica, comprobar tambi\u00e9n si hay \"p\u00e9rdida de fase\". Debido a que hay un circuito de detecci\u00f3n dentro del SAI para controlar la tensi\u00f3n de entrada en tiempo real, si hay una \"p\u00e9rdida de fase\", el valor medio trif\u00e1sico de la tensi\u00f3n de entrada debe ser inferior al l\u00edmite inferior del valor normal, y el circuito de detecci\u00f3n enviar\u00e1 una se\u00f1al para bloquear el arranque normal del SAI.<\/p><p>Si la tensi\u00f3n de entrada es normal y el SAI sigue sin arrancar con normalidad, en el caso de los SAI con entrada monof\u00e1sica, compruebe si el conductor de fase y el conductor neutro de la tensi\u00f3n de entrada est\u00e1n conectados al rev\u00e9s; en el caso de los SAI con entrada trif\u00e1sica, compruebe si la secuencia de fases de la tensi\u00f3n de entrada es correcta.<\/p><h4 id=\"UPS_frequently_switches_to_bypass_mode_during_operation\">El SAI cambia con frecuencia al modo de derivaci\u00f3n durante el funcionamiento<\/h4><p>Normalmente hay tres razones para que el funcionamiento normal del SAI pase al estado de bypass: En primer lugar, el propio SAI est\u00e1 averiado. En segundo lugar, el SAI est\u00e1 temporalmente sobrecargado. La tercera es el sobrecalentamiento. Por ejemplo, cuando el SAI tiene una carga pesada, y luego se ponen en marcha otras cargas, el SAI pasar\u00e1 al bypass debido a la \"sobrecarga\". Despu\u00e9s de que pase la corriente de impulso de la carga, el SAI pasar\u00e1 autom\u00e1ticamente al modo de trabajo normal. La ocurrencia frecuente de esta situaci\u00f3n es perjudicial para el trabajo estable del SAI, y debe tratarse en consecuencia.<\/p><p>Por ejemplo, la corriente de carga del microordenador en el momento del encendido es relativamente grande, y con la prolongaci\u00f3n del tiempo de encendido, la corriente de carga tiende gradualmente al valor normal. Despu\u00e9s del c\u00e1lculo, la corriente de carga del microordenador en el momento del encendido es aproximadamente 2-3 veces la del funcionamiento normal.<\/p><p>Este m\u00e9todo de control provocar\u00e1 inevitablemente que el SAI se sobrecargue y pase a bypass en el momento de la carga. Para evitar que esto ocurra, la carga debe aumentarse gradualmente en las condiciones normales de funcionamiento del SAI para dispersar la corriente de irrupci\u00f3n que la carga inicia al mismo tiempo.<\/p><p>Adem\u00e1s, la comparaci\u00f3n de la temperatura ambiente y la temperatura mostrada en la pantalla del SAI puede ayudar a determinar si el SAI pasa con frecuencia al modo de alimentaci\u00f3n de derivaci\u00f3n debido a una temperatura anormal.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33947\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature.jpg\" alt=\"si el SAI pasa con frecuencia al modo de alimentaci\u00f3n de derivaci\u00f3n debido a una temperatura anormal.\" width=\"1000\" height=\"562\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature-300x169.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature-768x432.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature-600x337.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"When_the_utility_power_is_interrupted,_the_UPS_will_also_automatically_stop\">Cuando se interrumpe el suministro el\u00e9ctrico, el SAI tambi\u00e9n se detiene autom\u00e1ticamente.<\/h4><p>Cuando se interrumpe la red el\u00e9ctrica, el SAI se apaga inmediatamente porque la bater\u00eda no puede mantener el suministro de energ\u00eda a la carga, lo que provoca la interrupci\u00f3n del suministro de energ\u00eda a la carga. En ese momento, debido al fallo de la bater\u00eda o al grave deterioro de su rendimiento, la bater\u00eda no tiene energ\u00eda suficiente para mantener el suministro el\u00e9ctrico a la carga cuando se interrumpe la red. Al comprobar la bater\u00eda, la calidad de la misma no puede medirse midiendo el nivel de la tensi\u00f3n en los bornes cuando la bater\u00eda est\u00e1 en vac\u00edo, sino que la bater\u00eda debe estar ligeramente cargada, en funci\u00f3n del cambio de su tensi\u00f3n en los bornes.<\/p><p>Cuando la bater\u00eda falla o su rendimiento se deteriora gravemente, aunque su tensi\u00f3n en bornes en vac\u00edo es b\u00e1sicamente normal, mientras est\u00e9 descargada, su tensi\u00f3n en bornes caer\u00e1 significativamente, y la ca\u00edda suele superar el rango admisible de la bater\u00eda. Al comprobar la bater\u00eda, el valor de carga de la misma est\u00e1 relacionado con su capacidad. Se recomienda tomar 70% de la capacidad nominal de la bater\u00eda como valor de la corriente de descarga.<\/p><h2 id=\"UPS_human_failure\">Fallo humano del SAI<\/h2><p>El llamado \"fallo humano\" se refiere al fallo causado por el comportamiento inadecuado de las personas o la ilusi\u00f3n de que algunos son fallos reales, mientras que otros no lo son en absoluto. Los fallos humanos de los SAI pueden dividirse a grandes rasgos en: fallos de sospecha, fallos de experiencia, fallos de conocimiento, fallos de traspaso, fallos operativos, fallos ambientales, fallos de retraso, fallos de selecci\u00f3n y fallos de mantenimiento.<\/p><h4 id=\"Suspected_failure\">Sospecha de fallo<\/h4><p>Como su nombre indica, la supuesta aver\u00eda no es realmente una aver\u00eda. Esta situaci\u00f3n suele deberse a la ilusi\u00f3n del personal de guardia. Por ejemplo, cuando el sistema SAI redundante en paralelo de dos m\u00e1quinas funciona con normalidad, el encargado abre la puerta delantera del armario y de repente se encuentra con que hay dos luces encendidas en un panel de control, pero en su impresi\u00f3n, una deber\u00eda estar encendida, por lo que piensa que el SAI est\u00e1 averiado. A toda prisa, se apag\u00f3 el inversor de este SAI y se invit\u00f3 urgentemente al fabricante a repararlo.<\/p><p>Cuando lleg\u00f3 el t\u00e9cnico de mantenimiento, comprob\u00f3 que todo era normal tras poner en marcha el SAI. El oficial de guardia pens\u00f3 que el panel de control del SAI defectuoso a\u00fan ten\u00eda dos luces indicadoras encendidas. Result\u00f3 que el SAI deb\u00eda tener dos luces encendidas cuando funcionaba como motor principal. S\u00f3lo se encendi\u00f3 una luz. La ocurrencia de esta situaci\u00f3n se debe principalmente a la ausencia del vigilante formado originalmente, o a la rotaci\u00f3n del vigilante con el vigilante sin formaci\u00f3n.<\/p><h4 id=\"Knowledge_failure\">Fallo de conocimiento<\/h4><p>La aparici\u00f3n de este tipo de situaciones se debe principalmente a la falta de conocimientos te\u00f3ricos b\u00e1sicos de algunos usuarios. Hay muchos ejemplos de este tipo, y adem\u00e1s el usuario lo considera un fallo real y exige al comerciante que lo repare o compense. Por ejemplo, un SAI trif\u00e1sico de 30 kV-A descubri\u00f3 que un m\u00f3dulo de potencia del equipo estaba quemado.<\/p><p>Entonces, el usuario confirm\u00f3 que estaba causado por la \"deriva del punto cero\" de la tensi\u00f3n trif\u00e1sica del SAI, y negoci\u00f3 con el comerciante del SAI, dici\u00e9ndole que el SAI ten\u00eda un problema y hab\u00eda que revisarlo o sustituirlo inmediatamente. Dado que los usuarios plantean cuestiones tan serias, los proveedores deben tom\u00e1rselas en serio. Despu\u00e9s de comprobar la tensi\u00f3n de salida trif\u00e1sica del SAI, es de 220V, 219V, 219V, la simetr\u00eda es muy buena, y el punto cero no deriva. El da\u00f1o del m\u00f3dulo de potencia del nuevo equipo es debido a su problema de calidad, y no hay ning\u00fan problema despu\u00e9s de reemplazarlo.<\/p><p>En general, la diferencia de tensi\u00f3n trif\u00e1sica inferior a 2% puede ignorarse. En la actualidad, la mayor\u00eda de los SAI tienen la capacidad de ajustar autom\u00e1ticamente el desequilibrio de tensi\u00f3n de fase inferior a 2% cuando la carga trif\u00e1sica est\u00e1 desequilibrada 100%. La llamada carga trif\u00e1sica desequilibrada 100% significa que una o dos fases de la salida trif\u00e1sica del SAI est\u00e1n completamente cargadas (es decir, cada fase est\u00e1 llena de 1\/3 de la capacidad nominal del SAI).<\/p><p>Mientras que las otras dos o una fase est\u00e1n descargadas. Por ejemplo, para un SAI de 30kV-A, el valor de plena carga de una fase es de 10kV-A, que no es como algunos entienden: la corriente de una fase es de 1A y la de la otra de 2A, y su desequilibrio se considera de 50%. En realidad no puede entenderse as\u00ed. Por otro lado, si la corriente de una fase es 1A y la corriente de la otra fase es cero, \u00a1entonces su desequilibrio tambi\u00e9n es 100%! Esto es cierto literalmente, pero no por definici\u00f3n.<\/p><p>Otro ejemplo es que algunos usuarios han equipado el SAI con bater\u00edas con una vida \u00fatil de 3 a 5 a\u00f1os, y la temperatura del entorno el\u00e9ctrico a menudo supera los 30\u00b0C en verano, y nunca se ha cortado el suministro el\u00e9ctrico despu\u00e9s de m\u00e1s de dos a\u00f1os de uso. Nunca se ha descargado, y el estado de la bater\u00eda puede imaginarse. Justo en este momento, el corte de corriente de la red el\u00e9ctrica, y el tiempo de descarga de la bater\u00eda es inferior a 1\/3 del tiempo nominal. Esto se debe principalmente a que el usuario no realiza un mantenimiento regular de la bater\u00eda de acuerdo con los requisitos pertinentes del manual de funcionamiento del SAI.<\/p><h4 id=\"Operation_failure\">Fallo de funcionamiento<\/h4><p>Para un funcionamiento seguro y fiable del SAI, los distintos productos disponen de su propio conjunto de procedimientos de funcionamiento seguro, que se incluyen en el manual para que los usuarios puedan consultarlos. Siga este procedimiento para garantizar el funcionamiento seguro del SAI, de lo contrario puede haber problemas. Algunos usuarios operan arbitrariamente de acuerdo con su propio entendimiento, y a veces hay problemas. Tambi\u00e9n hay fallos de funcionamiento no intencionados, como romper accidentalmente un dispositivo vecino al desmontar un dispositivo durante el mantenimiento. Se produce un fallo secundario.<\/p><p>Al comprobar la aver\u00eda, la punta de prueba para la medici\u00f3n cortocircuita por error algunos dos puntos; al conectar la bater\u00eda externa, los polos positivo y negativo son err\u00f3neos, lo que destruir\u00e1 el inversor. Uno o varios bornes de conexi\u00f3n de la bater\u00eda no est\u00e1n apretados o se ha olvidado el interruptor de la bater\u00eda Est\u00e1 cerrado, y la bater\u00eda no se descargar\u00e1 cuando falle la red. Si la conexi\u00f3n de entrada\/salida no est\u00e1 apretada, provocar\u00e1 la falsa aparici\u00f3n del fallo de CA. La oficina de suministro el\u00e9ctrico har\u00e1 que la secuencia de fases original sea incorrecta al renovar o reparar la l\u00ednea, lo que provocar\u00e1 que el SAI no pueda arrancar o que el interruptor falle.<\/p><p>Olvidarse de arrancar el inversor despu\u00e9s de encender el SAI, provocar\u00e1 un fallo de apagado cuando se corte la red; el personal de servicio arrojar\u00e1 comida en la sala de m\u00e1quinas o cerca de la sala de servicio, lo que atraer\u00e1 a los ratones, roer\u00e1n los cables o irrumpir\u00e1n en la m\u00e1quina, provocando fallos. O, como el chasis no es estanco, el lagarto taladra la m\u00e1quina y cortocircuita algunas partes de la placa de circuitos, provocando un fallo. El cable de se\u00f1al remota sin apantallar discurre en paralelo con la l\u00ednea de alimentaci\u00f3n de CA, y se producen interferencias de acoplamiento que provocan aver\u00edas.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33946\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure.jpg\" alt=\"Si olvida arrancar el inversor despu\u00e9s de encender el SAI, se producir\u00e1 un fallo de apagado.\" width=\"1000\" height=\"750\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure-300x225.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure-768x576.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure-600x450.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"Delay_failure\">Fallo de retardo<\/h4><p>Debido a la negligencia del personal de guardia, no se detectaron a tiempo los indicios de aver\u00eda, o se detect\u00f3 la aver\u00eda causada por no ser tratada a tiempo. Es decir, si estos fallos se descubren y se tratan a tiempo, se pueden evitar fallos posteriores.<\/p><p>Por ejemplo, en un sistema SAI redundante paralelo de dos m\u00e1quinas, la carga se divide uniformemente entre las dos m\u00e1quinas. En ocasiones, algunos SAI hacen que uno de los inversores se apague debido a la coincidencia de ciertas condiciones, y la carga se transfiere en ese momento. En el SAI que no se apaga, esta situaci\u00f3n se mostrar\u00e1 en el panel. Si el responsable se da cuenta a tiempo, basta con pulsar de nuevo el bot\u00f3n de arranque del variador apagado para arrancar el variador.<\/p><p>Si el personal de guardia no se da cuenta a tiempo, cuando se interrumpa la alimentaci\u00f3n de red, se convertir\u00e1 en una fuente de alimentaci\u00f3n aut\u00f3noma, en primer lugar, la capacidad de sobrecarga se debilitar\u00e1 y, en segundo lugar, el tiempo de reserva de la bater\u00eda se reducir\u00e1 a la mitad (cuando cada SAI tenga bater\u00edas de la misma capacidad). En caso de sobrecarga, se cortar\u00e1 toda la alimentaci\u00f3n.<\/p><p>Otro ejemplo es que cuando la bater\u00eda funciona en condiciones insatisfactorias, especialmente si no se ha cargado y descargado durante mucho tiempo, debe reforzarse la vigilancia. Si se detecta una bater\u00eda con una capacidad significativamente reducida, debe sustituirse inmediatamente. Otro ejemplo es que los fusibles y conectores del SAI del veh\u00edculo o buque se aflojan con facilidad debido a las constantes vibraciones, lo que provoca aver\u00edas.<\/p><p>Dado que el fusible est\u00e1 en funcionamiento durante mucho tiempo, se ablanda debido al calor y se hunde y dobla en el centro cuando vibra. En este momento, si no se sustituye a tiempo, puede romperse en cualquier momento, provocando fallos indebidos.<\/p><h4 id=\"Maintenance_failure\">Fallo de mantenimiento<\/h4><p>El mantenimiento regular del SAI es necesario, pero dicho mantenimiento debe contar con una serie de procedimientos estrictos.<br \/>La falta de mantenimiento regular o irregular de la m\u00e1quina es una causa importante de aver\u00eda. Por ejemplo, algunos SAI no reciben mantenimiento durante mucho tiempo, por lo que se encuentran con que la m\u00e1quina es inestable o se apaga o no puede arrancar, por lo que tienen que solicitar reparaciones.<\/p><p>Tras abrir la caja, el polvo mezclado con iones conductores llen\u00f3 toda la m\u00e1quina, cubri\u00f3 la placa de circuitos, se mezcl\u00f3 con vapor de agua y destruy\u00f3 el estado normal de funcionamiento del circuito. Despu\u00e9s de limpiar estos objetos extra\u00f1os con un secador de pelo, la m\u00e1quina volvi\u00f3 a la normalidad.<\/p><p>Por otro lado, tambi\u00e9n hay problemas en el mantenimiento: despu\u00e9s de reparar el SAI, el personal de mantenimiento conecta la red de CA al terminal de entrada, pero se olvida de arrancar el inversor o cerrar el interruptor de la bater\u00eda. Cuando se produce el siguiente fallo de red, el SAI El inversor no arranca o se apaga sin alimentaci\u00f3n de bater\u00eda.<\/p><p>Cuando una parte considerable del paquete de bater\u00edas se ha da\u00f1ado por motivos ambientales, el usuario sustituye indebidamente s\u00f3lo las bater\u00edas manifiestamente defectuosas. Cuando se produzca el siguiente fallo en la red el\u00e9ctrica, es posible que una de las bater\u00edas no sustituidas se desconecte y no pueda descargarse. Electricidad, o incluso si puede descargar electricidad, la capacidad de la bater\u00eda vieja se ver\u00e1 muy reducida debido a la influencia de la bater\u00eda vieja. La capacidad de la bater\u00eda nueva no se aprovechar\u00e1 al m\u00e1ximo, sino que se acortar\u00e1 su vida \u00fatil. Despu\u00e9s de sustituir la bater\u00eda, olv\u00eddese de apretar el extremo de conexi\u00f3n , no podr\u00e1 descargar electricidad cuando se utilice.<\/p><p>Si las herramientas, componentes, tornillos, tuercas, arandelas se olvidan en la m\u00e1quina despu\u00e9s de la reparaci\u00f3n, o el enchufe no est\u00e1 fijado, se producir\u00e1 un fallo.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33948\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure.jpg\" alt=\"Si las herramientas, componentes, tornillos, tuercas, arandelas se olvidan en la m\u00e1quina despu\u00e9s de la reparaci\u00f3n, o el enchufe no est\u00e1 fijado, se producir\u00e1 un fallo.\" width=\"1000\" height=\"667\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure-300x200.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure-768x512.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure-600x400.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"Experience_failure\">Fracaso de la experiencia<\/h4><p>La experiencia es un activo valioso, pero a la hora de resolver problemas, tambi\u00e9n se debe analizar la situaci\u00f3n espec\u00edfica en detalle, de lo contrario, las generalizaciones basadas \u00fanicamente en la experiencia a menudo conducir\u00e1n a problemas. Por ejemplo, una vez un usuario con experiencia en SAIs de la marca A fue a operar un SAI de la marca B, sin leer el manual, arranc\u00f3 con CC, porque todos los SAIs con los que estaba familiarizado se pod\u00edan arrancar con CC, aunque no pudiera arrancarlo, ten\u00eda una forma.<\/p><p>Sin embargo, esta m\u00e1quina en s\u00ed no tiene una funci\u00f3n de arranque de CC, por supuesto, no puede arrancar, por lo que abri\u00f3 la caja y utiliz\u00f3 un destornillador para ver el rel\u00e9 y apu\u00f1al\u00f3 el inversor. El inversor comenz\u00f3 a arrancar, pero inmediatamente hubo un humo blanco, y el tubo de alimentaci\u00f3n se da\u00f1\u00f3 as\u00ed. . No sab\u00eda que el SAI con funci\u00f3n de arranque de CC tiene un procedimiento determinado al arrancar: despu\u00e9s de encender el interruptor de arranque de CC, primero se establece el estado de funcionamiento del circuito de control, y despu\u00e9s de que sea normal, se acciona el tubo de potencia del inversor para lograr el prop\u00f3sito de arranque normal. .<\/p><p>Sin embargo, como aqu\u00ed no hay funci\u00f3n de arranque de CC, el inversor tambi\u00e9n arranca mientras el circuito de control est\u00e1 en proceso de establecer el estado de funcionamiento. El estado inestable del proceso de transici\u00f3n hace que los dos tubos de potencia del mismo brazo del inversor se enciendan al mismo tiempo y se quemen.<\/p><h4 id=\"Handover_failure\">Fallo de transferencia<\/h4><p>Este tipo de fallo se debe principalmente a la ignorancia del personal de guardia. Por ejemplo, hay una empresa de valores que adquiri\u00f3 un SAI con conexi\u00f3n en caliente de doble m\u00e1quina, con un retardo total de 4 horas (es decir, el retardo de cada SAI es de 2 horas).<\/p><p>En menos de un a\u00f1o, la empresa traslad\u00f3 el sistema sin notificarlo al fabricante del SAI sin autorizaci\u00f3n. Se desmont\u00f3 en dos SAI individuales para su uso, de modo que el retardo original de 4h se ha convertido en un \u00fanico retardo de 2h. Poco despu\u00e9s, un corte prolongado de la red el\u00e9ctrica cost\u00f3 a la empresa importantes p\u00e9rdidas.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>how to use ups\uff1aups failure analysis Troubleshooting method Observation method Graded compression test Other special methods UPS common faults Invariant Unregulated voltage Not charging Can not use mains electricity UPS cannot start normally UPS frequently switches to bypass mode during operation When the utility power is interrupted, the UPS will also automatically stop UPS human [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":33939,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[210,187,151,161],"tags":[7,117,130,153],"class_list":["post-33938","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-battery-industry","category-battery-management-system","category-lithium-ion-battery-knowledge","category-ups","tag-battery","tag-battery-cell","tag-lithium-battery","tag-lithium-ion-battery"],"modified_by":"tycorun666","_links":{"self":[{"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/posts\/33938","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/comments?post=33938"}],"version-history":[{"count":0,"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/posts\/33938\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/media\/33939"}],"wp:attachment":[{"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/media?parent=33938"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/categories?post=33938"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.takomabattery.com\/es\/wp-json\/wp\/v2\/tags?post=33938"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}