{"id":33938,"date":"2022-02-14T05:38:35","date_gmt":"2022-02-14T05:38:35","guid":{"rendered":"https:\/\/www.takomabattery.com\/?p=33938"},"modified":"2022-04-20T02:29:01","modified_gmt":"2022-04-20T02:29:01","slug":"how-to-use-ups-ups-failure-analysis","status":"publish","type":"post","link":"https:\/\/www.takomabattery.com\/fr\/how-to-use-ups-ups-failure-analysis\/","title":{"rendered":"Comment utiliser l'analyse des d\u00e9faillances des ups\uff1aups ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"33938\" class=\"elementor elementor-33938\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9496242 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9496242\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7c4b602\" data-id=\"7c4b602\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5eea69b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5eea69b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ae9bbf3\" data-id=\"ae9bbf3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b153248 elementor-widget elementor-widget-heading\" data-id=\"b153248\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">comment utiliser les ups\uff1aups pour l'analyse des d\u00e9faillances<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1c5f788 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1c5f788\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-37bc313\" data-id=\"37bc313\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-175ef07 elementor-widget elementor-widget-text-editor\" data-id=\"175ef07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div style=\"padding-left: 2.2em; padding-right: 2.2em; line-height: 40px;\"><div style=\"border: 2px solid #ccc;\"><ol style=\"padding-left: 2.2em; line-height: 40px;\"><li><a href=\"#Troubleshooting_method\">M\u00e9thode de d\u00e9pannage<\/a><ol style=\"counter-reset: item;\"><li><a href=\"#Observation_method\">M\u00e9thode d'observation<\/a><\/li><li><a href=\"#Graded_compression_test\">Essai de compression gradu\u00e9e<\/a><\/li><li><a href=\"#Other_special_methods\">Autres m\u00e9thodes sp\u00e9ciales<\/a><\/li><\/ol><\/li><li><a href=\"#UPS_common_faults\">D\u00e9fauts courants de l'ASI<\/a><ol style=\"counter-reset: item;\"><li><a href=\"#Invariant\">Invariant<\/a><\/li><li><a href=\"#Unregulated_voltage\">Tension non r\u00e9gul\u00e9e<\/a><\/li><li><a href=\"#Not_charging\">Pas de charge<\/a><\/li><li><a href=\"#Can_not_use_mains_electricity\">Ne peut pas utiliser l'\u00e9lectricit\u00e9 du r\u00e9seau<\/a><\/li><li><a href=\"#UPS_cannot_start_normally\">L'onduleur ne peut pas d\u00e9marrer normalement<\/a><\/li><li><a href=\"#UPS_frequently_switches_to_bypass_mode_during_operation\">L'onduleur passe fr\u00e9quemment en mode de d\u00e9rivation pendant le fonctionnement.<\/a><\/li><li><a href=\"#When_the_utility_power_is_interrupted,_the_UPS_will_also_automatically_stop\">Lorsque l'alimentation \u00e9lectrique est interrompue, l'onduleur s'arr\u00eate aussi automatiquement<\/a><\/li><\/ol><\/li><li><a href=\"#UPS_human_failure\">D\u00e9faillance humaine de l'UPS<\/a><ol style=\"counter-reset: item;\"><li><a href=\"#Suspected_failure\">D\u00e9faillance pr\u00e9sum\u00e9e<\/a><\/li><li><a href=\"#Knowledge_failure\">D\u00e9faut de connaissance<\/a><\/li><li><a href=\"#Operation_failure\">\u00c9chec de l'op\u00e9ration<\/a><\/li><li><a href=\"#Delay_failure\">D\u00e9faut de d\u00e9lai<\/a><\/li><li><a href=\"#Maintenance_failure\">D\u00e9faut de maintenance<\/a><\/li><li><a href=\"#Experience_failure\">\u00c9chec de l'exp\u00e9rience<\/a><\/li><li><a href=\"#Handover_failure\">\u00c9chec du transfert<\/a><\/li><\/ol><\/li><\/ol><\/div><p>Lorsque le syst\u00e8me ASI tombe en panne, il faut d'abord en trouver la cause et d\u00e9terminer s'il s'agit de la charge ou du syst\u00e8me ASI, de l'h\u00f4te ou du bloc-batterie. Bien que l'onduleur h\u00f4te soit dot\u00e9 d'une fonction d'autocontr\u00f4le des d\u00e9faillances, de nombreux travaux d'analyse et de test sont encore n\u00e9cessaires pour r\u00e9parer le point de d\u00e9faillance.<\/p><p>Lorsque l'onduleur de la charge importante tombe en panne, il ne faut pas l'arr\u00eater aveugl\u00e9ment, mais utiliser son by-pass pour continuer \u00e0 fournir de l'\u00e9nergie, puis en rechercher la cause et d\u00e9terminer si le d\u00e9faut se situe au niveau de la charge ou du syst\u00e8me d'onduleur. Si le syst\u00e8me ASI tombe en panne, d\u00e9terminez si la d\u00e9faillance se situe au niveau de l'h\u00f4te de l'ASI ou du bloc-batterie.<\/p><p>En outre, si la partie autotest \u00e9choue, le contenu du d\u00e9faut affich\u00e9 peut \u00eatre erron\u00e9. En cas de panne de l'ordinateur h\u00f4te, de rupture du fusible ou de br\u00fblure de l'appareil, il est n\u00e9cessaire de trouver la cause et d'\u00e9liminer la panne avant de red\u00e9marrer, faute de quoi la panne du syst\u00e8me ASI s'aggravera.<\/p><p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-33941\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand.jpg\" alt=\"il est n\u00e9cessaire de trouver la cause et d&#039;\u00e9liminer la d\u00e9faillance avant de red\u00e9marrer, sinon la d\u00e9faillance du syst\u00e8me ASI s&#039;aggravera.\" width=\"1000\" height=\"678\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand-300x203.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand-768x521.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/it-is-necessary-to-find-out-the-cause-and-eliminate-the-failure-before-restarting-otherwise-the-failure-of-the-UPS-system-will-further-expand-600x407.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h2 id=\"Troubleshooting_method\">M\u00e9thode de d\u00e9pannage<\/h2><p>L'\u00e9quipement ASI est une alimentation \u00e9lectrique sans interruption, et sa charge exige que l'alimentation \u00e9lectrique ne soit pas interrompue. Si l'ASI rencontre un probl\u00e8me, la charge connect\u00e9e en sera in\u00e9vitablement affect\u00e9e. Par cons\u00e9quent, le personnel charg\u00e9 de l'exploitation et de la maintenance de l'ASI doit bien conna\u00eetre l'\u00e9quipement utilis\u00e9. Il doit \u00eatre en mesure de traiter les pannes courantes en temps utile. Les paragraphes suivants pr\u00e9sentent plusieurs m\u00e9thodes de base pour le d\u00e9pannage.<\/p><h4 id=\"Observation_method\">M\u00e9thode d'observation<\/h4><p>La m\u00e9thode d'observation est la m\u00e9thode la plus simple, la plus directe et la plus pratique pour le d\u00e9pannage des \u00e9quipements. Cette m\u00e9thode consiste \u00e0 utiliser les sens humains pour juger initialement et \u00e9liminer les d\u00e9faillances de l'\u00e9quipement. Lorsque l'on utilise la m\u00e9thode d'observation pour d\u00e9tecter les d\u00e9faillances, on peut aller du simple au complexe, de l'externe \u00e0 l'interne, puis, sur la base d'une accumulation d'exp\u00e9rience appropri\u00e9e, se concentrer sur les circuits ou les pi\u00e8ces susceptibles d'\u00eatre d\u00e9fectueux. L'inspection a forc\u00e9ment un effet multiplicateur. La m\u00e9thode d'observation se concentre sur les quatre aspects que sont la vue, l'\u00e9coute, l'odorat et le toucher.<\/p><p>\"L'observation\" est la premi\u00e8re \u00e9tape de la d\u00e9faillance de contact, qui comprend : la v\u00e9rification de l'existence d'un court-circuit caus\u00e9 par des objets \u00e9trangers se chevauchant dans l'\u00e9quipement. Deuxi\u00e8mement, v\u00e9rifier s'il y a un circuit ouvert dans l'\u00e9quipement, ou s'il y a un fil gravement endommag\u00e9 ou cass\u00e9, en accordant une attention particuli\u00e8re au fil ou si les parties isolantes d'autres composants sont gravement endommag\u00e9es. Troisi\u00e8mement, v\u00e9rifiez si les composants sont d\u00e9form\u00e9s ou fissur\u00e9s. Quatri\u00e8mement, v\u00e9rifiez si les vis de connexion de l'\u00e9quipement sont desserr\u00e9es et si le contact de chaque connecteur est bon. Obscurcissement ou fum\u00e9e.<\/p><p>Le contenu \u00e0 observer comprend \u00e9galement l'enclenchement des contacteurs et des relais, l'\u00e9clairage et l'obscurit\u00e9 de divers indicateurs, l'\u00e9clatement des condensateurs \u00e9lectrolytiques et des condensateurs \u00e0 courant alternatif, etc. Une grande partie de la panne peut \u00eatre d\u00e9tect\u00e9e par l'observation, ce qui permet de remettre l'\u00e9quipement en service le plus rapidement possible.<\/p><p>\"L'\u00e9coute consiste \u00e0 v\u00e9rifier s'il y a un son anormal pendant le fonctionnement de l'\u00e9quipement. Pendant le fonctionnement de l'onduleur, le contacteur et le relais \u00e9mettent un son, et le transformateur, le r\u00e9acteur et d'autres bobines sous tension \u00e9mettent un son unique. Ces sons ob\u00e9issent \u00e0 certaines r\u00e8gles et \u00e0 certains rythmes. Si ces composants tombent en panne, leurs sons changent. C'est en fonction de ces changements que l'on peut d\u00e9terminer la d\u00e9faillance de l'\u00e9quipement de l'ASI.<\/p><p>L'\"odorat\" consiste \u00e0 utiliser les organes olfactifs de l'homme pour d\u00e9tecter les \u00e9quipements dans une certaine gamme. Par exemple, lorsque la couche ext\u00e9rieure isolante des conducteurs ou de certains composants est br\u00fbl\u00e9e ou d\u00e9coll\u00e9e en raison d'un passage excessif de courant, une odeur piquante et d\u00e9sagr\u00e9able est produite.<\/p><p>Par cons\u00e9quent, dans une certaine plage, cette odeur anormale peut rappeler au personnel de maintenance qu'il existe une situation anormale dans le fonctionnement de l'\u00e9quipement, et le d\u00e9faut peut \u00eatre \u00e9limin\u00e9 en recherchant soigneusement la source de l'odeur \u00e9trange. Le \"toucher\" consiste \u00e0 utiliser les mains pour entrer en contact avec certains composants susceptibles de tomber en panne ou avec des composants qui peuvent provoquer des pannes apr\u00e8s jugement, afin d'aider les op\u00e9rateurs et le personnel d'entretien \u00e0 trouver et \u00e0 \u00e9liminer les pannes.<\/p><p>Par exemple, si l'on soup\u00e7onne un d\u00e9faut de soudure ou de sueur froide, il peut \u00eatre d\u00e9tect\u00e9 en touchant l\u00e9g\u00e8rement ou en secouant, et la perception de la temp\u00e9rature peut \u00eatre d\u00e9termin\u00e9e par l'exp\u00e9rience. L'onduleur comporte de nombreux \u00e9l\u00e9ments chauffants. Lorsque l'\u00e9quipement fonctionne, le courant circule et la temp\u00e9rature de certains composants augmente. Tant que la temp\u00e9rature ne d\u00e9passe pas la valeur autoris\u00e9e, le fonctionnement de l'\u00e9quipement n'est pas affect\u00e9.<\/p><p><img decoding=\"async\" class=\"aligncenter size-full wp-image-33942\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected.jpg\" alt=\"Tant que la temp\u00e9rature ne d\u00e9passe pas la valeur autoris\u00e9e, l&#039;\u00e9tat de fonctionnement de l&#039;\u00e9quipement n&#039;est pas affect\u00e9.\" width=\"1000\" height=\"519\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected-300x156.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected-768x399.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/As-long-as-the-temperature-does-not-exceed-the-allowable-value-the-working-state-of-the-equipment-will-not-be-affected-600x311.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><p>Toutefois, si l'on constate qu'un certain composant est surchauff\u00e9 et que la temp\u00e9rature augmente soudainement, il se peut que l'\u00e9quipement soit tomb\u00e9 en panne ou qu'il tombe en panne. \u00c0 ce moment-l\u00e0, nous pouvons trouver la panne en fonction de la source de chaleur et analyser la cause. Le \"toucher\" n\u00e9cessite une exp\u00e9rience accumul\u00e9e dans le cadre d'un travail normal, mais il n'est pas permis de le manipuler. Pour les endroits o\u00f9 la temp\u00e9rature est \u00e9lev\u00e9e, la tension \u00e9lev\u00e9e ou tout autre contact g\u00eanant, il ne faut pas intervenir facilement afin d'\u00e9viter les blessures corporelles ou d'affecter le fonctionnement normal de l'\u00e9quipement.<\/p><p>En r\u00e9sum\u00e9, la m\u00e9thode d'observation permet de traiter directement et rapidement le d\u00e9faut. Les m\u00e9thodes d'observation, d'\u00e9coute, d'odorat et de toucher ne sont pas ind\u00e9pendantes les unes des autres et peuvent \u00eatre utilis\u00e9es seules ou en combinaison. Par exemple, en raison d'un courant de court-circuit, s'il est trop important pour provoquer la br\u00fblure d'un certain fil, le changement de sa couleur peut \u00eatre d\u00e9tect\u00e9 par l'observation, ou la transmission d'une odeur particuli\u00e8re peut \u00eatre per\u00e7ue par l'odorat, et la source de la panne peut \u00eatre trouv\u00e9e.<\/p><p>Enfin, il convient d'observer certains circuits pr\u00e9sentant un taux de d\u00e9faillance \u00e9lev\u00e9.<\/p><h4 id=\"Graded_compression_test\">Essai de compression gradu\u00e9e<\/h4><p>Dans le cadre du d\u00e9pannage de l'ASI, bien que la m\u00e9thode d'observation soit plus efficace, de nombreux d\u00e9fauts ne peuvent pas \u00eatre d\u00e9tect\u00e9s par la m\u00e9thode d'observation et doivent \u00eatre \u00e9valu\u00e9s par certaines m\u00e9thodes de test, afin de d\u00e9couvrir la cause du d\u00e9faut et de prendre les mesures de compression n\u00e9cessaires pour corriger le d\u00e9faut. R\u00e9duire jusqu'au d\u00e9pannage.<\/p><p>La compression hi\u00e9rarchique consiste \u00e0 analyser et \u00e0 juger certaines d\u00e9faillances dont la port\u00e9e n'est pas claire, puis \u00e0 les tester \u00e9tape par \u00e9tape pour les comprimer et les trouver. Il existe diff\u00e9rentes m\u00e9thodes de compression en fonction du type de d\u00e9faillance de l'\u00e9quipement ou des m\u00e9thodes de maintenance individuelles. Par exemple, il existe une m\u00e9thode de compression hi\u00e9rarchique + une m\u00e9thode de mesure de la r\u00e9sistance, une m\u00e9thode de compression hi\u00e9rarchique + une m\u00e9thode de mesure de la pression, etc.<\/p><p>Ces m\u00e9thodes sont indissociables des m\u00e9thodes statiques et dynamiques. La m\u00e9thode statique de mesure de la r\u00e9sistance est utilis\u00e9e pour v\u00e9rifier si le circuit est normal, et finalement le d\u00e9faut est comprim\u00e9 jusqu'\u00e0 un certain point ; la m\u00e9thode dynamique est utilis\u00e9e pour d\u00e9tecter si la tension et la forme d'onde du circuit concern\u00e9 sont normales lorsque l'\u00e9quipement fonctionne pour comprimer le d\u00e9faut. Ces deux m\u00e9thodes de maintenance augmentent la vitesse de maintenance en adoptant la m\u00e9thode de compression segment\u00e9e.<\/p><p>La m\u00e9thode de maintenance utilisant la compression de sous-section consiste \u00e0 analyser et \u00e0 d\u00e9terminer si le circuit concern\u00e9 est anormal en testant certaines valeurs de tension, valeurs de courant et formes d'onde. Par cons\u00e9quent, le personnel de maintenance doit \u00eatre capable de m\u00e9moriser et de tester correctement la forme d'onde normale, la valeur de la tension et la plage de valeurs du courant de certains points de travail importants.<\/p><p>Les principaux points de fonctionnement sont les suivants : Entr\u00e9e de l'alimentation CA, entr\u00e9e (sortie) du redresseur, entr\u00e9e (sortie) de l'onduleur, sortie du dispositif de filtrage, sortie de la batterie, dispositif de commutation haute puissance et chaque circuit imprim\u00e9 L'alimentation de travail, etc. suivie des points de tension et des points de forme d'onde pertinents dans chaque circuit de contr\u00f4le, comparez la situation de test avec la valeur normale, puis analysez l'\u00e9tendue de la panne. D\u00e9pannage plus rapide.<\/p><p>Pour le test de la valeur de la tension, de la valeur du courant et de la forme d'onde, si la valeur normale n'est pas claire, si les conditions le permettent, la tension, le courant et la forme d'onde du point correspondant du m\u00eame \u00e9quipement qui fonctionne normalement peuvent \u00eatre test\u00e9s. Les deux sont compar\u00e9s pour analyser et juger le d\u00e9faut.<\/p><h4 id=\"Other_special_methods\">Autres m\u00e9thodes sp\u00e9ciales<\/h4><p>Pour certains ph\u00e9nom\u00e8nes ou points de d\u00e9faillance particuliers, il est difficile de les \u00e9liminer par des m\u00e9thodes ordinaires, c'est pourquoi nous pouvons utiliser des m\u00e9thodes sp\u00e9ciales pour v\u00e9rifier et comprimer. Par exemple, un mauvais contact caus\u00e9 par la soudure \u00e0 froid, la soudure virtuelle, l'usure du contact, l'oxydation, la rouille, etc. peut facilement entra\u00eener un bon ou un mauvais fonctionnement de l'\u00e9quipement de l'ASI. Lorsqu'il est anormal, le personnel de maintenance le v\u00e9rifie et le comprime \u00e0 cet endroit, et le d\u00e9faut peut dispara\u00eetre soudainement. Pour les pannes intermittentes de ce type, il est g\u00e9n\u00e9ralement plus efficace d'utiliser la m\u00e9thode de vibration du robinet pour v\u00e9rifier.<\/p><p><img decoding=\"async\" class=\"aligncenter size-full wp-image-33943\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust.jpg\" alt=\"certains mauvais contacts caus\u00e9s par le soudage \u00e0 froid, le soudage virtuel, l&#039;usure des contacts, l&#039;oxydation, la rouille\" width=\"1000\" height=\"750\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust-300x225.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust-768x576.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/some-poor-contact-caused-by-cold-welding-virtual-welding-contact-wear-oxidation-rust-600x450.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><p>Dans la m\u00e9thode de vibration par taraudage, il convient de noter que la vibration par taraudage ne doit pas \u00eatre trop importante. En cas de doute sur une certaine pi\u00e8ce, il ne faut pas que le taraudage de cette pi\u00e8ce provoque des vibrations excessives \u00e0 d'autres endroits, et il ne faut pas que le taraudage excessif provoque de nouvelles d\u00e9faillances. L'op\u00e9ration ne peut \u00eatre effectu\u00e9e que mod\u00e9r\u00e9ment. Lorsque vous frappez, n'utilisez pas d'objets m\u00e9talliques pour \u00e9viter les rayures ou les courts-circuits.<\/p><p>L'\u00e9quipement ASI peut tomber en panne en raison de l'augmentation de la temp\u00e9rature ambiante ou de l'augmentation de la temp\u00e9rature de fonctionnement \u00e0 l'int\u00e9rieur de l'\u00e9quipement lui-m\u00eame. Apr\u00e8s une p\u00e9riode d'arr\u00eat, l'\u00e9quipement peut \u00eatre red\u00e9marr\u00e9 lorsque la temp\u00e9rature diminue, et l'\u00e9quipement peut \u00e0 nouveau fonctionner normalement. Cependant, lorsque la temp\u00e9rature de fonctionnement augmente, l'\u00e9quipement tombe \u00e0 nouveau en panne.<\/p><p>Pour ces ph\u00e9nom\u00e8nes anormaux dus \u00e0 l'\u00e9l\u00e9vation de la temp\u00e9rature, la meilleure m\u00e9thode de maintenance et de compression consiste \u00e0 utiliser la m\u00e9thode de chauffage local. La m\u00e9thode de chauffage local fait r\u00e9f\u00e9rence au d\u00e9pannage et \u00e0 la compression de l'\u00e9quipement. La source de chaleur peut \u00eatre un corps de chauffe de s\u00e9curit\u00e9 ou un s\u00e8che-cheveux, etc. Lors du chauffage local, si le syst\u00e8me ne fonctionne pas, cela indique que la performance thermique est mauvaise. L'\u00e9l\u00e9ment se trouve dans la zone de chauffage. Lors du chauffage local, la temp\u00e9rature doit \u00eatre correctement contr\u00f4l\u00e9e. Elle ne doit pas \u00eatre trop basse, car l'effet serait m\u00e9diocre ; elle ne doit pas \u00eatre trop \u00e9lev\u00e9e, car elle risquerait d'endommager les composants et de provoquer artificiellement de nouvelles pannes.<\/p><p>Pour certains d\u00e9fauts complexes, en particulier lorsque le principe de fonctionnement interne de certains composants n'est pas bien compris, lorsque l'inspection est limit\u00e9e \u00e0 un niveau ou \u00e0 une certaine section, on soup\u00e7onne que certains composants sont d\u00e9fectueux, on peut alors utiliser la m\u00e9thode alternative pour juger, la m\u00e9thode de substitution s'applique \u00e0 la m\u00eame carte de circuit imprim\u00e9, \u00e0 la m\u00eame unit\u00e9 de circuit ou \u00e0 un composant sp\u00e9cifique.<\/p><p>Par exemple, en cas de doute sur le caract\u00e8re normal ou non d'un certain composant, celui-ci peut \u00eatre remplac\u00e9 par des composants de m\u00eame type et de m\u00eame sp\u00e9cification. Pour voir si le ph\u00e9nom\u00e8ne de d\u00e9faillance de l'\u00e9quipement dispara\u00eet, pour certains composants dont il est difficile de d\u00e9terminer la sp\u00e9cification du mod\u00e8le, nous pouvons utiliser des composants similaires \u00e0 la place, et si le ph\u00e9nom\u00e8ne de d\u00e9faillance peut \u00eatre \u00e9limin\u00e9, cela signifie que la d\u00e9faillance est bien l\u00e0. La m\u00e9thode de substitution a un champ d'application tr\u00e8s large, en particulier pour les \u00e9quipements ASI import\u00e9s qui n'ont pas de sch\u00e9mas de circuit de r\u00e9f\u00e9rence ni d'indicateurs de param\u00e8tres sp\u00e9cifiques.<\/p><p>Il existe plusieurs m\u00e9thodes de maintenance pour les pannes d'ASI. Il est impossible de les r\u00e9sumer en d\u00e9tail ici. Il appartient \u00e0 chacun de les am\u00e9liorer en permanence dans le cadre du processus de d\u00e9pannage r\u00e9el et de r\u00e9sumer un ensemble de m\u00e9thodes de maintenance adapt\u00e9es \u00e0 son propre mode de pens\u00e9e.<\/p><h2 id=\"UPS_common_faults\">D\u00e9fauts courants de l'ASI<\/h2><p>Dans des circonstances normales, les d\u00e9fauts courants de la carte m\u00e8re de l'ASI sont les suivants : d\u00e9faut de mise en parall\u00e8le, d\u00e9faut d'inversion, d\u00e9faut de stabilisation, d\u00e9faut de charge, incapacit\u00e9 d'utiliser l'alimentation secteur, d\u00e9faut de batterie, d\u00e9faut de condensateur, d\u00e9faut d'interf\u00e9rence et panne. Lors de la remise en \u00e9tat de l'ASI, il convient de v\u00e9rifier d'abord la batterie, puis le circuit de la carte m\u00e8re. S'il s'av\u00e8re que le circuit de la carte m\u00e8re est d\u00e9fectueux, il convient de v\u00e9rifier d'abord le circuit d'alimentation du r\u00e9gulateur de tension secteur, puis le circuit de l'onduleur.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33945\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit.jpg\" alt=\"Lors de la r\u00e9vision de l&#039;ASI, il convient de v\u00e9rifier d&#039;abord la batterie, puis le circuit de la carte m\u00e8re.\" width=\"1000\" height=\"563\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit-300x169.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit-768x432.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-overhauling-the-UPS-the-battery-should-be-checked-first-followed-by-the-motherboard-circuit-600x338.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"Invariant\">Invariant<\/h4><p>Non-invers\u00e9 signifie que l'onduleur fonctionne normalement avec l'alimentation secteur, mais que la tension continue de la batterie ne peut pas \u00eatre convertie en tension alternative de 220V (ou 380V) lorsque l'alimentation secteur est interrompue. Dans ce cas, la tension de la batterie doit \u00eatre mesur\u00e9e en premier, car si la tension de la batterie est trop faible, le circuit de contr\u00f4le interrompra le fonctionnement du circuit de l'onduleur apr\u00e8s avoir d\u00e9tect\u00e9 le signal de faible tension de la batterie.<\/p><p>Ensuite, v\u00e9rifiez si l'alimentation auxiliaire est normale et si le tube inverseur et le tube d'entra\u00eenement sont endommag\u00e9s. Enfin, v\u00e9rifiez le circuit de protection de la sortie. Dans des circonstances normales, le point de d\u00e9faillance de l'ASI peut \u00eatre v\u00e9rifi\u00e9 et \u00e9limin\u00e9 gr\u00e2ce aux \u00e9tapes ci-dessus.<\/p><h4 id=\"Unregulated_voltage\">Tension non r\u00e9gul\u00e9e<\/h4><p>Pour l'ASI hors ligne, la tension non r\u00e9gul\u00e9e est divis\u00e9e en deux situations : la sortie n'est pas r\u00e9gul\u00e9e lorsque l'entr\u00e9e CA est introduite et la sortie de l'onduleur n'est pas r\u00e9gul\u00e9e. Lorsque l'alimentation commerciale est introduite, le processus de r\u00e9gulation de la tension de sortie est r\u00e9alis\u00e9 en connectant le relais et les diff\u00e9rentes prises du transformateur \u00e0 travers le circuit de r\u00e9gulation de la tension.<\/p><p>Le processus de r\u00e9gulation de la tension de sortie de l'onduleur est r\u00e9alis\u00e9 en contr\u00f4lant la largeur d'impulsion du signal carr\u00e9 par la d\u00e9tection de la tension de retour de l'onduleur. Si l'onduleur ne parvient pas \u00e0 stabiliser la tension, il suffit de v\u00e9rifier le circuit de contr\u00f4le de r\u00e9gulation de tension correspondant.<\/p><h4 id=\"Not_charging\">Pas de charge<\/h4><p>Le d\u00e9faut de non-charge est difficile \u00e0 trouver dans un environnement o\u00f9 l'alimentation secteur n'est pas fr\u00e9quemment interrompue, et il est tr\u00e8s nuisible, et il est susceptible de provoquer la mise au rebut anticip\u00e9e de la batterie parce qu'elle ne peut pas \u00eatre charg\u00e9e pendant une longue p\u00e9riode. La m\u00e9thode d'\u00e9valuation de ce d\u00e9faut est tr\u00e8s simple : il suffit de d\u00e9connecter la connexion entre le circuit de charge et la batterie pour \u00e9valuer la tension \u00e0 vide du circuit de charge.<\/p><p>Lorsqu'elle est normale, la tension d'une seule batterie de 12V est de 13,5V, et celle de deux batteries connect\u00e9es en s\u00e9rie est de 27V. Si la tension est anormale, le circuit de charge et le circuit de contr\u00f4le correspondant doivent \u00eatre v\u00e9rifi\u00e9s, en particulier le circuit de contr\u00f4le correspondant ; lorsque la tension du r\u00e9seau est trop faible ou interrompue, le circuit de charge s'arr\u00eate de fonctionner sous l'action du circuit de contr\u00f4le ; si le circuit de contr\u00f4le fonctionne mal et fonctionne mal, le circuit de charge ne fonctionnera pas.<\/p><h4 id=\"Can_not_use_mains_electricity\">Ne peut pas utiliser l'\u00e9lectricit\u00e9 du r\u00e9seau<\/h4><p>La sortie de l'onduleur est normale et il n'y a pas de sortie lorsque l'entr\u00e9e secteur est utilis\u00e9e. En effet, lorsque le circuit de d\u00e9tection du secteur d\u00e9tecte que la tension du secteur est trop faible ou trop \u00e9lev\u00e9e, il envoie un signal correspondant au circuit de commande, de sorte que ce dernier envoie une impulsion de commande pour couper le secteur. Le canal d'entr\u00e9e de l'alimentation, et faire passer l'onduleur \u00e0 l'\u00e9tat d'onduleur.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33944\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit.jpg\" alt=\"Lorsque le circuit de d\u00e9tection est normal, v\u00e9rifier enfin le circuit de conversion du relais.\" width=\"1000\" height=\"563\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit-300x169.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit-768x432.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/When-the-detection-circuit-is-normal-finally-check-the-relay-conversion-circuit-600x338.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><p>Lorsque le circuit de d\u00e9tection est normal, v\u00e9rifiez enfin le circuit de conversion du relais. En raison des diff\u00e9rents mod\u00e8les, la relation de contr\u00f4le et les types de circuits de protection sont \u00e9galement tr\u00e8s diff\u00e9rents. Il existe de nombreuses raisons pour expliquer le m\u00eame ph\u00e9nom\u00e8ne de d\u00e9faillance, mais d'apr\u00e8s l'exp\u00e9rience, les m\u00e9thodes d'inspection sont fondamentalement les m\u00eames.<\/p><h4 id=\"UPS_cannot_start_normally\">L'onduleur ne peut pas d\u00e9marrer normalement<\/h4><p>Dans des circonstances normales, l'onduleur en ligne fonctionnera automatiquement en mode d'alimentation par d\u00e9rivation tant que l'interrupteur d'entr\u00e9e est ferm\u00e9 et que la charge est directement aliment\u00e9e par le secteur. Lorsque l'onduleur d\u00e9marre pendant un certain temps, il passe automatiquement de l'alimentation par d\u00e9rivation \u00e0 l'alimentation par onduleur (mode de fonctionnement normal). S'il ne peut pas d\u00e9marrer normalement, cela signifie qu'il y a un probl\u00e8me avec la batterie ou l'onduleur. V\u00e9rifiez la batterie ou l'onduleur pour trouver la cause du probl\u00e8me.<\/p><p>Outre les facteurs internes de la machine, les raisons pour lesquelles l'onduleur ne peut pas d\u00e9marrer normalement doivent d'abord \u00eatre v\u00e9rifi\u00e9es si la tension d'entr\u00e9e est normale et, pour les onduleurs \u00e0 entr\u00e9e triphas\u00e9e, s'il y a une \"perte de phase\". L'onduleur \u00e9tant \u00e9quip\u00e9 d'un circuit de d\u00e9tection qui surveille la tension d'entr\u00e9e en temps r\u00e9el, en cas de \"perte de phase\", la valeur moyenne triphas\u00e9e de la tension d'entr\u00e9e doit \u00eatre inf\u00e9rieure \u00e0 la limite inf\u00e9rieure de la valeur normale, et le circuit de d\u00e9tection enverra un signal pour bloquer le d\u00e9marrage normal de l'onduleur.<\/p><p>Si la tension d'entr\u00e9e est normale et que l'ASI ne d\u00e9marre toujours pas normalement, pour les ASI \u00e0 entr\u00e9e monophas\u00e9e, v\u00e9rifiez si le fil sous tension et le fil neutre de la tension d'entr\u00e9e sont connect\u00e9s de mani\u00e8re invers\u00e9e, pour les ASI \u00e0 entr\u00e9e triphas\u00e9e, v\u00e9rifiez si la s\u00e9quence des phases de la tension d'entr\u00e9e est correcte.<\/p><h4 id=\"UPS_frequently_switches_to_bypass_mode_during_operation\">L'onduleur passe fr\u00e9quemment en mode de d\u00e9rivation pendant le fonctionnement.<\/h4><p>Il y a g\u00e9n\u00e9ralement trois raisons pour lesquelles le fonctionnement normal de l'onduleur passe \u00e0 l'\u00e9tat de d\u00e9rivation : Premi\u00e8rement, l'onduleur lui-m\u00eame est d\u00e9fectueux. Deuxi\u00e8mement, l'onduleur est temporairement surcharg\u00e9. La troisi\u00e8me est la surchauffe. Par exemple, lorsque l'onduleur a une charge importante et que d'autres charges sont d\u00e9marr\u00e9es, l'onduleur passe en mode bypass pour cause de \"surcharge\". Une fois que le courant d'impulsion de la charge est pass\u00e9, l'onduleur passe automatiquement en mode de fonctionnement normal. L'apparition fr\u00e9quente de cette situation est pr\u00e9judiciable \u00e0 la stabilit\u00e9 du fonctionnement de l'ASI et doit \u00eatre trait\u00e9e en cons\u00e9quence.<\/p><p>Par exemple, le courant de charge du micro-ordinateur au moment de la mise sous tension est relativement important, et avec la prolongation du temps de mise sous tension, le courant de charge tend progressivement vers la valeur normale. Apr\u00e8s calcul, le courant de charge du micro-ordinateur au moment du d\u00e9marrage est environ 2 \u00e0 3 fois sup\u00e9rieur \u00e0 celui du fonctionnement normal.<\/p><p>Une telle m\u00e9thode de contr\u00f4le entra\u00eenera in\u00e9vitablement une surcharge de l'onduleur et le passage en mode bypass au moment de la charge. Pour \u00e9viter cela, la charge doit \u00eatre augment\u00e9e progressivement dans les conditions normales de fonctionnement de l'onduleur afin de disperser le courant d'appel que la charge d\u00e9marre en m\u00eame temps.<\/p><p>En outre, la comparaison de la temp\u00e9rature ambiante et de la temp\u00e9rature affich\u00e9e sur l'\u00e9cran de l'onduleur peut aider \u00e0 d\u00e9terminer si l'onduleur passe fr\u00e9quemment en mode d'alimentation par d\u00e9rivation en raison d'une temp\u00e9rature anormale.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33947\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature.jpg\" alt=\"si l&#039;ASI passe fr\u00e9quemment en mode d&#039;alimentation par d\u00e9rivation en raison d&#039;une temp\u00e9rature anormale\" width=\"1000\" height=\"562\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature-300x169.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature-768x432.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/whether-the-UPS-is-frequently-switched-to-the-bypass-power-supply-mode-due-to-abnormal-temperature-600x337.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"When_the_utility_power_is_interrupted,_the_UPS_will_also_automatically_stop\">Lorsque l'alimentation \u00e9lectrique est interrompue, l'onduleur s'arr\u00eate aussi automatiquement<\/h4><p>Lorsque l'alimentation \u00e9lectrique est interrompue, l'onduleur s'arr\u00eate imm\u00e9diatement car la batterie ne peut pas maintenir l'alimentation de la charge, ce qui entra\u00eene une interruption de l'alimentation de la charge. \u00c0 ce moment-l\u00e0, en raison de la d\u00e9faillance de la batterie ou de la d\u00e9t\u00e9rioration grave de ses performances, la batterie ne dispose pas de suffisamment d'\u00e9nergie pour maintenir l'alimentation de la charge lorsque le r\u00e9seau est interrompu. Lors du contr\u00f4le de la batterie, la qualit\u00e9 de la batterie ne peut pas \u00eatre mesur\u00e9e en mesurant le niveau de la tension aux bornes lorsque la batterie est \u00e0 vide, mais la batterie doit \u00eatre l\u00e9g\u00e8rement charg\u00e9e, en fonction du changement de sa tension aux bornes.<\/p><p>Lorsque la batterie tombe en panne ou que ses performances sont s\u00e9rieusement d\u00e9t\u00e9rior\u00e9es, bien que sa tension aux bornes \u00e0 vide soit fondamentalement normale, tant qu'elle est d\u00e9charg\u00e9e, sa tension aux bornes chute de mani\u00e8re significative, et cette chute d\u00e9passe souvent la plage admissible de la batterie. Lors de la v\u00e9rification de la batterie, la valeur de charge de la batterie est li\u00e9e \u00e0 la capacit\u00e9 de la batterie. Il est recommand\u00e9 de prendre 70% de la capacit\u00e9 nominale de la batterie comme valeur du courant de d\u00e9charge.<\/p><h2 id=\"UPS_human_failure\">D\u00e9faillance humaine de l'UPS<\/h2><p>L'expression \"d\u00e9faillance humaine\" fait r\u00e9f\u00e9rence \u00e0 la d\u00e9faillance caus\u00e9e par le comportement inappropri\u00e9 des personnes ou par l'illusion que certaines d\u00e9faillances sont r\u00e9elles, alors que d'autres ne le sont pas du tout. Les d\u00e9faillances humaines des ASI peuvent \u00eatre grossi\u00e8rement divis\u00e9es en : d\u00e9faillances pr\u00e9sum\u00e9es, d\u00e9faillances li\u00e9es \u00e0 l'exp\u00e9rience, d\u00e9faillances li\u00e9es aux connaissances, d\u00e9faillances li\u00e9es au transfert, d\u00e9faillances op\u00e9rationnelles, d\u00e9faillances li\u00e9es \u00e0 l'environnement, d\u00e9faillances li\u00e9es aux retards, d\u00e9faillances li\u00e9es \u00e0 la s\u00e9lection et d\u00e9faillances li\u00e9es \u00e0 la maintenance.<\/p><h4 id=\"Suspected_failure\">D\u00e9faillance pr\u00e9sum\u00e9e<\/h4><p>Comme son nom l'indique, le soi-disant \u00e9chec pr\u00e9sum\u00e9 n'est en fait pas un \u00e9chec. Cette situation est g\u00e9n\u00e9ralement due \u00e0 l'illusion du personnel de service. Par exemple, lorsque le syst\u00e8me ASI redondant parall\u00e8le \u00e0 deux machines fonctionne normalement, le pr\u00e9pos\u00e9 ouvre la porte avant de l'armoire et constate soudain que deux voyants d'un panneau de commande sont allum\u00e9s, alors que, selon lui, un seul devrait l'\u00eatre, de sorte qu'il pense que l'ASI est d\u00e9fectueuse. Dans l'urgence, l'onduleur de cette ASI a \u00e9t\u00e9 mis hors tension et le fabricant a \u00e9t\u00e9 invit\u00e9 d'urgence \u00e0 le r\u00e9parer.<\/p><p>Apr\u00e8s l'arriv\u00e9e de l'ing\u00e9nieur de maintenance, il a constat\u00e9 que tout \u00e9tait normal apr\u00e8s le d\u00e9marrage de l'onduleur. L'officier de service pensait que le panneau de commande d\u00e9fectueux de l'ASI avait encore deux voyants allum\u00e9s. Il s'est av\u00e9r\u00e9 que l'onduleur devait avoir deux voyants allum\u00e9s lorsqu'il fonctionnait comme le moteur principal. Il n'y avait qu'un voyant allum\u00e9. Cette situation est principalement due \u00e0 l'absence du gardien form\u00e9 \u00e0 l'origine, ou \u00e0 la rotation du gardien avec un gardien non form\u00e9.<\/p><h4 id=\"Knowledge_failure\">D\u00e9faut de connaissance<\/h4><p>L'\u00e9mergence de telles situations est principalement due au manque de connaissances th\u00e9oriques de base de certains utilisateurs. Les exemples de ce type sont nombreux et l'utilisateur consid\u00e8re \u00e9galement qu'il s'agit d'une v\u00e9ritable panne et demande au commer\u00e7ant de la r\u00e9parer ou de la compenser. Par exemple, un onduleur triphas\u00e9 30kV-A a constat\u00e9 qu'un module de puissance de l'\u00e9quipement \u00e9tait grill\u00e9.<\/p><p>L'utilisateur a donc confirm\u00e9 que le probl\u00e8me \u00e9tait d\u00fb \u00e0 la \"d\u00e9rive du point z\u00e9ro\" de la tension triphas\u00e9e de l'ASI et a n\u00e9goci\u00e9 avec le vendeur de l'ASI en disant que l'ASI avait un probl\u00e8me et devait \u00eatre v\u00e9rifi\u00e9e ou remplac\u00e9e imm\u00e9diatement. Puisque les utilisateurs soul\u00e8vent des questions aussi graves, les fournisseurs doivent les prendre au s\u00e9rieux. Apr\u00e8s v\u00e9rification de la tension de sortie triphas\u00e9e de l'ASI, celle-ci est de 220V, 219V, 219V, la sym\u00e9trie est tr\u00e8s bonne et le point z\u00e9ro ne d\u00e9rive pas. L'endommagement du module de puissance du nouvel \u00e9quipement est d\u00fb \u00e0 un probl\u00e8me de qualit\u00e9, et il n'y a pas de probl\u00e8me apr\u00e8s son remplacement.<\/p><p>En r\u00e8gle g\u00e9n\u00e9rale, la diff\u00e9rence de tension triphas\u00e9e inf\u00e9rieure \u00e0 2% peut \u00eatre ignor\u00e9e. \u00c0 l'heure actuelle, la plupart des onduleurs ont la capacit\u00e9 de r\u00e9gler automatiquement le d\u00e9s\u00e9quilibre de tension de phase inf\u00e9rieur \u00e0 2% lorsque la charge triphas\u00e9e est d\u00e9s\u00e9quilibr\u00e9e de 100%. La charge triphas\u00e9e d\u00e9s\u00e9quilibr\u00e9e de 100% signifie qu'une ou deux phases de la sortie triphas\u00e9e de l'onduleur sont enti\u00e8rement charg\u00e9es (c'est-\u00e0-dire que chaque phase est pleine \u00e0 1\/3 de la capacit\u00e9 nominale de l'onduleur).<\/p><p>Alors que les deux autres phases ou une phase sont d\u00e9charg\u00e9es. Par exemple, pour un onduleur de 30kV-A, la valeur de pleine charge d'une phase est de 10kV-A, ce qui n'est pas ce que certains comprennent : le courant d'une phase est de 1A et le courant de l'autre phase est de 2A, et leur d\u00e9s\u00e9quilibre est consid\u00e9r\u00e9 comme \u00e9tant de 50%. En fait, ce n'est pas comme cela qu'il faut l'entendre. D'autre part, si le courant d'une phase est de 1A et que le courant de l'autre phase est nul, leur d\u00e9s\u00e9quilibre est \u00e9galement de 100% ! C'est vrai litt\u00e9ralement, mais pas par d\u00e9finition.<\/p><p>Autre exemple : certains utilisateurs ont \u00e9quip\u00e9 l'onduleur de batteries d'une dur\u00e9e de vie de 3 \u00e0 5 ans, alors que la temp\u00e9rature de l'environnement \u00e9lectrique d\u00e9passe souvent 30\u00b0C en \u00e9t\u00e9, et que l'alimentation \u00e9lectrique n'a jamais \u00e9t\u00e9 coup\u00e9e apr\u00e8s plus de deux ans d'utilisation. Elle n'a jamais \u00e9t\u00e9 d\u00e9charg\u00e9e et l'\u00e9tat de la batterie peut \u00eatre imagin\u00e9. En ce moment m\u00eame, il y a eu une coupure de courant et la dur\u00e9e de d\u00e9charge de la batterie est inf\u00e9rieure \u00e0 1\/3 de la dur\u00e9e nominale. Cela s'explique principalement par le fait que l'utilisateur n'entretient pas r\u00e9guli\u00e8rement la batterie conform\u00e9ment aux exigences du manuel d'utilisation de l'onduleur.<\/p><h4 id=\"Operation_failure\">\u00c9chec de l'op\u00e9ration<\/h4><p>Pour garantir un fonctionnement s\u00fbr et fiable de l'onduleur, les diff\u00e9rents produits disposent de leur propre ensemble de proc\u00e9dures de fonctionnement s\u00fbr, qui sont d\u00e9crites dans le manuel afin que les utilisateurs puissent s'y r\u00e9f\u00e9rer. Suivez cette proc\u00e9dure pour garantir un fonctionnement s\u00fbr de l'onduleur, faute de quoi des probl\u00e8mes pourraient survenir. Certains utilisateurs op\u00e8rent de mani\u00e8re arbitraire, selon leur propre compr\u00e9hension, et il arrive que des probl\u00e8mes surviennent. Il existe \u00e9galement des d\u00e9faillances involontaires, telles que la rupture accidentelle d'un dispositif voisin lors du d\u00e9montage d'un dispositif au cours de la maintenance. Un d\u00e9faut secondaire se produit.<\/p><p>Lors de la v\u00e9rification du d\u00e9faut, la sonde du fil d'essai pour la mesure court-circuite par erreur certains points ; lors de la connexion de la batterie externe, les p\u00f4les positif et n\u00e9gatif sont erron\u00e9s, ce qui d\u00e9truira l'onduleur. Une ou plusieurs bornes de connexion de la batterie ne sont pas serr\u00e9es ou l'interrupteur de batterie est oubli\u00e9 Il est ferm\u00e9 et la batterie ne sera pas d\u00e9charg\u00e9e en cas de coupure de courant. Si la connexion entr\u00e9e\/sortie n'est pas serr\u00e9e, cela provoquera une fausse apparence de panne de courant alternatif. Lors de la r\u00e9novation ou de la r\u00e9paration de la ligne, le bureau de l'alimentation \u00e9lectrique peut modifier l'ordre des phases d'origine, ce qui entra\u00eene l'impossibilit\u00e9 de d\u00e9marrer l'onduleur ou une d\u00e9faillance de l'interrupteur.<\/p><p>Le personnel de service jette de la nourriture dans la salle des machines ou \u00e0 proximit\u00e9 de celle-ci, ce qui attire les souris, ronge les c\u00e2bles ou s'introduit dans la machine, provoquant des pannes. Ou parce que le ch\u00e2ssis n'est pas \u00e9tanche, le l\u00e9zard perce la machine et court-circuite certaines parties de la carte de circuit imprim\u00e9, ce qui provoque une panne. Le c\u00e2ble de signal \u00e0 distance non blind\u00e9 passe en parall\u00e8le avec la ligne d'alimentation en courant alternatif, et des interf\u00e9rences de couplage se produisent et provoquent des pannes.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33946\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure.jpg\" alt=\"Oublier de d\u00e9marrer l&#039;onduleur apr\u00e8s la mise sous tension de l&#039;onduleur entra\u00eenera une d\u00e9faillance de l&#039;arr\u00eat.\" width=\"1000\" height=\"750\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure-300x225.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure-768x576.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/Forgetting-to-start-the-inverter-after-the-UPS-is-powered-on-it-will-cause-a-shutdown-failure-600x450.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"Delay_failure\">D\u00e9faut de d\u00e9lai<\/h4><p>En raison de la n\u00e9gligence du personnel de service, les signes de d\u00e9faillance n'ont pas \u00e9t\u00e9 d\u00e9tect\u00e9s \u00e0 temps, ou la d\u00e9faillance caus\u00e9e par le fait de ne pas avoir \u00e9t\u00e9 trait\u00e9e \u00e0 temps a \u00e9t\u00e9 d\u00e9tect\u00e9e. En d'autres termes, si ces d\u00e9faillances sont d\u00e9couvertes et trait\u00e9es \u00e0 temps, les d\u00e9faillances ult\u00e9rieures peuvent \u00eatre \u00e9vit\u00e9es.<\/p><p>Par exemple, dans un syst\u00e8me redondant parall\u00e8le \u00e0 deux machines, la charge est \u00e9galement r\u00e9partie entre les deux machines. Certains onduleurs provoquent parfois l'arr\u00eat de l'un des onduleurs en raison de la co\u00efncidence de certaines conditions, et la charge est transf\u00e9r\u00e9e \u00e0 ce moment-l\u00e0. Sur l'onduleur qui n'est pas arr\u00eat\u00e9, cette situation est affich\u00e9e sur le panneau. Si l'agent de service s'en aper\u00e7oit \u00e0 temps, il lui suffit d'appuyer \u00e0 nouveau sur le bouton de d\u00e9marrage de l'onduleur arr\u00eat\u00e9 pour le remettre en marche.<\/p><p>Si le personnel de service ne s'en aper\u00e7oit pas \u00e0 temps, lorsque l'alimentation secteur est interrompue, l'onduleur devient une source d'alimentation autonome. D'une part, la capacit\u00e9 de surcharge est affaiblie et, d'autre part, la dur\u00e9e de la batterie de secours est r\u00e9duite de moiti\u00e9 (lorsque chaque onduleur est \u00e9quip\u00e9 de batteries de m\u00eame capacit\u00e9). En cas de surcharge, toute l'alimentation sera coup\u00e9e.<\/p><p>Autre exemple : lorsque la batterie fonctionne dans des conditions insatisfaisantes, en particulier si elle n'a pas \u00e9t\u00e9 charg\u00e9e ou d\u00e9charg\u00e9e pendant une longue p\u00e9riode, la surveillance doit \u00eatre renforc\u00e9e. Lorsqu'une batterie dont la capacit\u00e9 est consid\u00e9rablement r\u00e9duite est d\u00e9tect\u00e9e, elle doit \u00eatre remplac\u00e9e imm\u00e9diatement. Autre exemple : les fusibles et les connecteurs de l'onduleur du v\u00e9hicule ou du navire sont faciles \u00e0 desserrer en raison des vibrations constantes, ce qui entra\u00eene des d\u00e9faillances.<\/p><p>Comme le fusible reste longtemps sous tension, il se ramollit sous l'effet de la chaleur et se plie en son milieu lorsqu'il vibre. \u00c0 ce moment-l\u00e0, s'il n'est pas remplac\u00e9 \u00e0 temps, il peut se rompre \u00e0 tout moment, entra\u00eenant des d\u00e9faillances inutiles.<\/p><h4 id=\"Maintenance_failure\">D\u00e9faut de maintenance<\/h4><p>Une maintenance r\u00e9guli\u00e8re de l'ASI est n\u00e9cessaire, mais cette maintenance doit faire l'objet d'un ensemble de proc\u00e9dures strictes.<br \/>L'absence d'entretien r\u00e9gulier ou irr\u00e9gulier de la machine est une cause importante de d\u00e9faillance. Par exemple, certains onduleurs ne sont pas entretenus pendant une longue p\u00e9riode, de sorte que les utilisateurs constatent que la machine est instable, qu'elle s'arr\u00eate ou qu'elle ne peut pas \u00eatre d\u00e9marr\u00e9e, ce qui les oblige \u00e0 demander des r\u00e9parations.<\/p><p>Apr\u00e8s l'ouverture du bo\u00eetier, la poussi\u00e8re m\u00e9lang\u00e9e \u00e0 des ions conducteurs a rempli l'ensemble de la machine, recouvert le circuit imprim\u00e9, s'est m\u00e9lang\u00e9e \u00e0 la vapeur d'eau et a d\u00e9truit l'\u00e9tat de fonctionnement normal du circuit. Apr\u00e8s avoir nettoy\u00e9 ces corps \u00e9trangers \u00e0 l'aide d'un s\u00e8che-cheveux, la machine est revenue \u00e0 la normale.<\/p><p>D'autre part, il existe \u00e9galement des probl\u00e8mes de maintenance : apr\u00e8s la r\u00e9paration de l'onduleur, le personnel de maintenance ajoute du courant alternatif \u00e0 la borne d'entr\u00e9e, mais oublie de d\u00e9marrer l'onduleur ou de fermer l'interrupteur de batterie. Lors de la prochaine coupure de courant, l'onduleur ne d\u00e9marre pas ou s'\u00e9teint sans batterie.<\/p><p>Lorsqu'une grande partie du bloc-batterie a \u00e9t\u00e9 endommag\u00e9e pour des raisons environnementales, l'utilisateur ne remplace que les batteries manifestement d\u00e9fectueuses. Lors de la prochaine coupure de courant, l'une des batteries non remplac\u00e9es risque d'\u00eatre d\u00e9connect\u00e9e et de ne pas pouvoir \u00eatre d\u00e9charg\u00e9e. La capacit\u00e9 de l'ancienne batterie sera fortement r\u00e9duite en raison de l'influence de l'ancienne batterie sur l'\u00e9lectricit\u00e9, ou m\u00eame si elle peut d\u00e9charger de l'\u00e9lectricit\u00e9. La capacit\u00e9 de la nouvelle batterie ne sera pas enti\u00e8rement utilis\u00e9e, mais raccourcira sa dur\u00e9e de vie. Apr\u00e8s avoir remplac\u00e9 la pile, oubliez de resserrer l'extr\u00e9mit\u00e9 de connexion, elle ne pourra pas d\u00e9charger d'\u00e9lectricit\u00e9 lorsqu'elle sera utilis\u00e9e.<\/p><p>Si les outils, les composants, les vis, les \u00e9crous et les rondelles sont oubli\u00e9s dans la machine apr\u00e8s la r\u00e9paration, ou si la prise de courant n'est pas fix\u00e9e, cela entra\u00eenera une d\u00e9faillance.<\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-33948\" src=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure.jpg\" alt=\"Si des outils, des composants, des vis, des \u00e9crous, des rondelles sont oubli\u00e9s dans la machine apr\u00e8s la r\u00e9paration, ou si la prise de courant n&#039;est pas fix\u00e9e, cela entra\u00eenera une d\u00e9faillance.\" width=\"1000\" height=\"667\" srcset=\"https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure.jpg 1000w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure-300x200.jpg 300w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure-768x512.jpg 768w, https:\/\/www.takomabattery.com\/wp-content\/uploads\/2022\/02\/If-tools-components-screws-nuts-washers-are-forgotten-in-the-machine-after-repair-or-the-plug-socket-is-not-fastened-it-will-lead-to-failure-600x400.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p><h4 id=\"Experience_failure\">\u00c9chec de l'exp\u00e9rience<\/h4><p>L'exp\u00e9rience est un atout pr\u00e9cieux, mais lorsque vous r\u00e9solvez des probl\u00e8mes, vous devez \u00e9galement analyser la situation sp\u00e9cifique en d\u00e9tail, sinon les g\u00e9n\u00e9ralisations bas\u00e9es sur l'exp\u00e9rience seule conduiront souvent \u00e0 des probl\u00e8mes. Par exemple, un utilisateur exp\u00e9riment\u00e9 dans les ASI de la marque A est all\u00e9 faire fonctionner une ASI de la marque B, sans lire le manuel, il a d\u00e9marr\u00e9 en courant continu, parce que toutes les ASI qu'il connaissait pouvaient \u00eatre d\u00e9marr\u00e9es en courant continu, m\u00eame s'il ne pouvait pas les d\u00e9marrer, il avait un moyen de le faire.<\/p><p>Il a donc ouvert le bo\u00eetier et a utilis\u00e9 un tournevis pour voir le relais et a poignard\u00e9 l'onduleur. L'onduleur a commenc\u00e9 \u00e0 d\u00e9marrer, mais une fum\u00e9e blanche s'est imm\u00e9diatement d\u00e9gag\u00e9e et le tube de puissance a \u00e9t\u00e9 endommag\u00e9 comme suit. . Il ne savait pas que l'onduleur dot\u00e9 d'une fonction de d\u00e9marrage en courant continu a une certaine proc\u00e9dure de d\u00e9marrage : apr\u00e8s que l'interrupteur de d\u00e9marrage en courant continu est activ\u00e9, l'\u00e9tat de fonctionnement du circuit de contr\u00f4le est d'abord \u00e9tabli, et une fois qu'il est normal, le tube d'alimentation de l'onduleur est entra\u00een\u00e9 pour atteindre l'objectif du d\u00e9marrage normal. .<\/p><p>Cependant, comme il n'y a pas de fonction de d\u00e9marrage CC, l'onduleur d\u00e9marre \u00e9galement alors que le circuit de commande est en train d'\u00e9tablir l'\u00e9tat de fonctionnement. L'instabilit\u00e9 du processus de transition fait que les deux tubes de puissance situ\u00e9s sur le m\u00eame bras de l'onduleur sont allum\u00e9s en m\u00eame temps et br\u00fblent.<\/p><h4 id=\"Handover_failure\">\u00c9chec du transfert<\/h4><p>Ce type de d\u00e9faillance est principalement d\u00fb \u00e0 l'ignorance du personnel de service. Par exemple, une soci\u00e9t\u00e9 de titres a achet\u00e9 un onduleur avec une connexion de secours \u00e0 chaud \u00e0 deux machines, avec un d\u00e9lai total de 4 heures (c'est-\u00e0-dire que le d\u00e9lai de chaque onduleur est de 2 heures).<\/p><p>En moins d'un an, l'entreprise a d\u00e9plac\u00e9 le syst\u00e8me sans en avertir le fabricant de l'onduleur sans autorisation. Le syst\u00e8me a \u00e9t\u00e9 d\u00e9mont\u00e9 en deux onduleurs pour \u00eatre utilis\u00e9, de sorte que le d\u00e9lai initial de 4 heures est devenu un d\u00e9lai unique de 2 heures. Peu de temps apr\u00e8s, une panne de courant prolong\u00e9e a entra\u00een\u00e9 des pertes importantes pour l'entreprise.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>how to use ups\uff1aups failure analysis Troubleshooting method Observation method Graded compression test Other special methods UPS common faults Invariant Unregulated voltage Not charging Can not use mains electricity UPS cannot start normally UPS frequently switches to bypass mode during operation When the utility power is interrupted, the UPS will also automatically stop UPS human [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":33939,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_lmt_disableupdate":"","_lmt_disable":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[210,187,151,161],"tags":[7,117,130,153],"class_list":["post-33938","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-battery-industry","category-battery-management-system","category-lithium-ion-battery-knowledge","category-ups","tag-battery","tag-battery-cell","tag-lithium-battery","tag-lithium-ion-battery"],"modified_by":"tycorun666","_links":{"self":[{"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/posts\/33938","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/comments?post=33938"}],"version-history":[{"count":0,"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/posts\/33938\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/media\/33939"}],"wp:attachment":[{"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/media?parent=33938"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/categories?post=33938"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.takomabattery.com\/fr\/wp-json\/wp\/v2\/tags?post=33938"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}